Evidence map›Paper›PMID 29911907›Full record

ArticleThe Angle orthodontist2018

Scanning electron microscopy evaluation of aligner fit on teeth.

Edoardo Mantovani, Enrico Castroflorio, Gabriele Rossini, Francesco Garino, Giovanni Cugliari, Andrea Deregibus, Tommaso Castroflorio

Open access · diamondAbstract readEvaluation Study
In one paragraph

Article in The Angle orthodontist, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
1.9field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 46 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Accuracy of a clear aligner hybrid approach in managing severe rotations of rounded teeth : A retrospective cohort study.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Edoardo Mantovani
Enrico Castroflorio
Gabriele Rossini
Francesco Garino
Giovanni Cugliari
Andrea Deregibus
Tommaso Castroflorio
University of Turin · ITMary Lyon Centre at MRC Harwell · GBPolytechnic University of Turin · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe fitting of aligners on anchorage teeth is a crucial factor in clear aligner orthodontics. The purpose of this experimental study was to evaluate the fitting of two aligner systems, Invisalign and CA-Clear Aligner, using scanning electron microscopy (SEM). MATERIALS AND

methodsPassive aligners (Invisalign and CA-Clear Aligner) were adapted on resin casts obtained by stereolithography (STL) files of a patient, and then sectioned buccolingually. Upper and lower central incisors, upper and lower first premolars, and upper and lower first molars were the regions analyzed. Representative microphotographs of sections were taken with a scanning electron microscope (SEM); a total of 160 micrometric measurements were obtained and analyzed with ANOVA tests.

resultsInvisalign provided an overall better fit on lower incisors ( F = 11.48, P = .0095) and on lower molars ( F = 19.93, P = .0012). Considering the different regions, Invisalign provided better fit at the gingival edge of the buccal aspect on lower incisors ( F = 11.33, P = 0.0056) and at the gingival edge of the lingual aspect on upper premolars ( F =5.34, P = 0.0047). On the upper molars, Invisalign provided better fit at the gingival edge of the buccal aspect, while CA-Clear Aligner provided better fit at the buccal maximum convexity, on the buccal cusp, on the occlusal groove and at the palatal cusp. On lower molars, Invisalign showed a more accurate fit at the buccal aspect points.

conclusionsInvisalign and CA-Clear Aligner exhibited comparable fit on anchorage teeth. Invisalign provided better fit at the gingival edges of aligners, while the CA-Clear Aligner provided better fit on complex occlusal surfaces.

Indexed as

Orthodontic Appliances, RemovableDental Casting TechniqueHumansMicroscopy, Electron, ScanningStereolithographyAlignersCA-Clear AlignerFittingInvisalignMicroscopySEM

Identifiers

PMID29911907
PMCPMC8183126
OpenAlexW2808042553

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.