Evidence map›Paper›PMID 29909528›Full record

ArticleInternational journal of computer assisted radiology and surgery2018

Accuracy of computer-aided design models of the jaws produced using ultra-low MDCT doses and ASIR and MBIR.

Asma'a A Al-Ekrish, Sara A Alfadda, Wadea Ameen, Romed Hörmann, Wolfgang Puelacher, Gerlig Widmann

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Asma'a A Al-EkrishDepartment of Oral Medicine and Diagnostic Sciences, College of Dentistry, King Saud University, 60169, Riyadh, 11545, Saudi Arabia. aalekrish@ksu.edu.sa.ORCID http://orcid.org/0000-0003-2158-1230
Sara A AlfaddaDepartment of Prosthetic Dental Sciences, College of Dentistry, King Saud University, 60169, Riyadh, 11545, Saudi Arabia.
Wadea AmeenDepartment of Industrial Engineering, Advanced Manufacturing Institute, College of Engineering, King Saud University, 800, Riyadh, 11421, Saudi Arabia.
Romed HörmannDivision of Clinical and Functional Anatomy, Medical University of Innsbruck, Müllerstrasse 59, 6020, Innsbruck, Austria.
Wolfgang PuelacherDepartment of CMF Surgery, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria.
Gerlig WidmannDepartment of Radiology, Medical University of Innsbruck, Anichstr. 35, 6020, Innsbruck, Austria.

Funding

Deanship of Scientific Research at King Saud University RGP-1438-037
6 · The paper itself

Abstract

purposeTo compare the surface of computer-aided design (CAD) models of the maxilla produced using ultra-low MDCT doses combined with filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) reconstruction techniques with that produced from a standard dose/FBP protocol.

methodsA cadaveric completely edentulous maxilla was imaged using a standard dose protocol (CTDIvol: 29.4 mGy) and FBP, in addition to 5 low dose test protocols (LD1-5) (CTDIvol: 4.19, 2.64, 0.99, 0.53, and 0.29 mGy) reconstructed with FBP, ASIR 50, ASIR 100, and MBIR. A CAD model from each test protocol was superimposed onto the reference model using the 'Best Fit Alignment' function. Differences between the test and reference models were analyzed as maximum and mean deviations, and root-mean-square of the deviations, and color-coded models were obtained which demonstrated the location, magnitude and direction of the deviations.

resultsBased upon the magnitude, size, and distribution of areas of deviations, CAD models from the following protocols were comparable to the reference model: FBP/LD1; ASIR 50/LD1 and LD2; ASIR 100/LD1, LD2, and LD3; MBIR/LD1. The following protocols demonstrated deviations mostly between 1-2 mm or under 1 mm but over large areas, and so their effect on surgical guide accuracy is questionable: FBP/LD2; MBIR/LD2, LD3, LD4, and LD5. The following protocols demonstrated large deviations over large areas and therefore were not comparable to the reference model: FBP/LD3, LD4, and LD5; ASIR 50/LD3, LD4, and LD5; ASIR 100/LD4, and LD5.

conclusionsWhen MDCT is used for CAD models of the jaws, dose reductions of 86% may be possible with FBP, 91% with ASIR 50, and 97% with ASIR 100. Analysis of the stability and accuracy of CAD/CAM surgical guides as directly related to the jaws is needed to confirm the results.

Indexed as

Computer-Aided DesignModels, AnatomicAlgorithmsCadaverFemaleHumansImage Processing, Computer-AssistedMaleMaxillaRadiation DosageRadiographic Image Interpretation, Computer-AssistedRadionuclide ImagingTomography, X-Ray ComputedComputer-aided surgeryDentalDigitalImage-guided surgeryMultidetector computed tomographyRadiation dosageRadiography