Evidence map›Paper›PMID 29902533›Full record

ArticleBiomaterials2018

Multimode ultrasound viscoelastography for three-dimensional interrogation of microscale mechanical properties in heterogeneous biomaterials.

Xiaowei Hong, Ramkumar T Annamalai, Tyler S Kemerer, Cheri X Deng, Jan P Stegemann

Abstract read
In one paragraph

Article in Biomaterials, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xiaowei HongDepartment of Biomedical Engineering, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, MI, MI 48109, USA.
Ramkumar T AnnamalaiDepartment of Biomedical Engineering, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, MI, MI 48109, USA.
Tyler S KemererDepartment of Biomedical Engineering, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, MI, MI 48109, USA.
Cheri X DengDepartment of Biomedical Engineering, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, MI, MI 48109, USA. Electronic address: cxdeng@umich.edu.
Jan P StegemannDepartment of Biomedical Engineering, University of Michigan, 2200 Bonisteel Boulevard, Ann Arbor, MI, MI 48109, USA. Electronic address: jpsteg@umich.edu.

Funding

Microscale Mechanobiology for Musculoskeletal Tissue Engineering using Advanced Ultrasound TechniquesR01DE026630 · NIDCR · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI DENG, CHERI X, STEGEMANN, JAN P. · 2017 to 2021
$1.8M
Bone Regeneration Using Osteogenic and Vasculogenic Tissue ModulesR01AR062636 · NIAMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI STEGEMANN, JAN P. · 2014 to 2018
$1.7M
NIAMS NIH HHS R01 AR062636NIDCR NIH HHS R01 DE026630
6 · The paper itself

Abstract

Both static and time-dependent mechanical factors can have a profound impact on cell and tissue function, but it is challenging to measure the mechanical properties of soft materials at the scale which cells sense. Multimode ultrasound viscoelastography (MUVE) uses focused ultrasound pulses to both generate and image deformations within soft hydrogels non-invasively, at sub-millimeter resolution, and in 3D. The deformation and strain over time data are used to extract quantitative parameters that describe both the elastic and viscoelastic properties of the material. MUVE was used in creep mode to characterize the viscoelastic properties of 3D agarose, collagen, and fibrin hydrogels. Quantitative comparisons were made by extracting characteristic viscoelastic parameters using Burger's lumped parameter constitutive model. Spatial resolution of the MUVE technique was found to be approximately 200 μm, while detection sensitivity, defined as the capability to differentiate between materials based on mechanical property differences, was approximately 0.2 kPa using agarose hydrogels. MUVE was superior to nanoindentation and shear rheometry in generating consistent microscale measurements of viscoelastic behavior in soft materials. These results demonstrate that MUVE is a rapid, quantitative, and accurate method to measure the viscoelastic mechanical properties of soft 3D hydrogels at the microscale, and is a promising technique to study the development of native and engineered tissues over time.

Indexed as

Elasticity Imaging TechniquesMaterials TestingMechanical PhenomenaBiocompatible MaterialsCollagenDurapatiteFibrinHydrogelsSepharoseTransducersViscosityBiocompatible MaterialsCollagenDurapatiteFibrinHydrogelsSepharoseBiomaterialsElastographyHydrogelsMechanobiologyUltrasound imagingViscoelasticity

Identifiers

PMID29902533
PMCPMC7369000

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.