Anti-scatter grid artifact elimination for high-resolution x-ray imaging detectors without a prior scatter distribution profile.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A unified scatter rejection and correction method for cone beam computed tomography.Medical physics · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Using anti-scatter grids with high-resolution imaging detectors could result in grid-line artifacts, with increasing severity as detector resolution improves. Grid-line mask subtraction can result in residual artifacts that are due to residual scatter penetrating the grid and not subtracted. By subtracting this residual scatter, the grid artifacts can be minimized. In the previous works, an initial residual-scatter estimate was derived by placing lead markers on a test object; however, any change in the object geometry requires a new scatter estimate. Such a method is impractical to implement during a clinical procedure. In this work, we present a new method to derive the initial scatter estimate to eliminate grid-line artifacts during a procedure. A standard stationary Smit-Roentgen x-ray grid (line density - 70 lines/cm, grid ratio - 13:1) was used with a high-resolution CMOS detector (Dexela Model 1207, pixel size - 75 μm) to image an anthropomorphic head phantom. The initial scatter estimate was derived from the image itself and the grid artifacts were eliminated using recursive correction estimation; this result was compared to that with the estimate derived from placing lead markers on the phantom. In both cases, the contrast-to-noise ratio (CNR) was improved compared to the original image with grid artifacts. Percentage differences in CNR's for three regions between the images corrected with the two estimates were less than 5%. With the new method no a priori scatter distribution profiles are needed, eliminating the need to have libraries of pre-calculated scatter profiles and making the implementation more clinically practical.