Evidence map›Paper›PMID 29899587›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2018

Initial investigations of a special high-definition (Hi-Def) zoom capability in a new detector system for neuro-interventional procedures.

S V Setlur Nagesh, A Shankar, J Krebs, J Hinaman, D R Bednarek, S Rudin

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

S V Setlur NageshToshiba Stroke and Vascular Research Center, University at Buffalo, SUNY.
A ShankarToshiba Stroke and Vascular Research Center, University at Buffalo, SUNY.
J KrebsToshiba Stroke and Vascular Research Center, University at Buffalo, SUNY.
J HinamanToshiba Stroke and Vascular Research Center, University at Buffalo, SUNY.
D R BednarekToshiba Stroke and Vascular Research Center, University at Buffalo, SUNY.
S RudinToshiba Stroke and Vascular Research Center, University at Buffalo, SUNY.
Toshiba (Japan) · JPToshiba (United States) · US

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
NIBIB NIH HHS R01 EB002873
6 · The paper itself

Abstract

Real-time visualization of fine details ranging to 100 um or less in neuro-vascular imaging guided interventions is important. A separate high-resolution detector mounted on a standard flat panel detector (FPD) was previously reported. This device had to be rotated mechanically into position over the FPD for high resolution imaging. Now, the new detector reported here has a high definition (Hi-Def) zoom capability along with the FPD built into one unified housing. The new detector enables rapid switching, by the operator between Hi-Def and FPD modes. Standard physical metrics comparing the new Hi-Def modes with those of the FPD are reported, demonstrating improved imaging resolution and noise capability at patient doses similar to those used for the FPD. Semi-quantitative subjective studies involving qualitative clinician feedback on images of interventional devices such as a Pipeline Embolization Device (PED) acquired in both Hi-Def and FPD modes are presented. The PED is deployed in a patient specific 3D printed neuro-vascular phantom embedded inside realistic bone and with tissue attenuating material. Field-of-view (FOV), exposure and magnification were kept constant for FPD and Hi-Def modes. Static image comparisons of the same view of the PED within the phantom were rated by expert interventionalists who chose from the following ratings: Similar, Better, or Superior. Generally, the Hi-Def zoomed images were much preferred over the FPD, indicating the potential to improve endovascular procedures and hence outcomes using such a Hi-Def feature.

Identifiers

PMID29899587
PMCPMC5994606
OpenAlexW2791562475

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.