Evidence map›Paper›PMID 29897358›Full record

ArticleLab on a chip2018

Additive manufacturing of three-dimensional (3D) microfluidic-based microelectromechanical systems (MEMS) for acoustofluidic applications.

Ellen Cesewski, Alexander P Haring, Yuxin Tong, Manjot Singh, Rajan Thakur, Sahil Laheri, Kaitlin A Read, Michael D Powell, Kenneth J Oestreich, Blake N Johnson

Abstract read
In one paragraph

Article in Lab on a chip, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Trial
  2. Metamaterials and Fluid Flows.Nature communications · 2026
    Review
  3. Review
  4. 3D printing of micro-nano devices and their applications.Microsystems & nanoengineering · 2025
    Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Review
  10. Article
  11. Electrochemical biosensors for pathogen detection.Biosensors & bioelectronics · 2020
    Review
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ellen CesewskiDepartment of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA 24061, USA. bnj@vt.edu.
Alexander P Haring
Yuxin Tong
Manjot Singh
Rajan Thakur
Sahil Laheri
Kaitlin A Read
Michael D Powell
Kenneth J Oestreich
Blake N Johnson

Funding

Regulation of T helper cell differentiation by integrated STAT and Ikaros zinc finger transcription factor mechanismsR56AI127800 · NIAID · VIRGINIA POLYTECHNIC INST AND ST UNIV · PI OESTREICH, KENNETH JOSEPH · 2017 to 2017
$263k
NIAID NIH HHS R56 AI127800
6 · The paper itself

Abstract

Three-dimensional (3D) printing now enables the fabrication of 3D structural electronics and microfluidics. Further, conventional subtractive manufacturing processes for microelectromechanical systems (MEMS) relatively limit device structure to two dimensions and require post-processing steps for interface with microfluidics. Thus, the objective of this work is to create an additive manufacturing approach for fabrication of 3D microfluidic-based MEMS devices that enables 3D configurations of electromechanical systems and simultaneous integration of microfluidics. Here, we demonstrate the ability to fabricate microfluidic-based acoustofluidic devices that contain orthogonal out-of-plane piezoelectric sensors and actuators using additive manufacturing. The devices were fabricated using a microextrusion 3D printing system that contained integrated pick-and-place functionality. Additively assembled materials and components included 3D printed epoxy, polydimethylsiloxane (PDMS), silver nanoparticles, and eutectic gallium-indium as well as robotically embedded piezoelectric chips (lead zirconate titanate (PZT)). Electrical impedance spectroscopy and finite element modeling studies showed the embedded PZT chips exhibited multiple resonant modes of varying mode shape over the 0-20 MHz frequency range. Flow visualization studies using neutrally buoyant particles (diameter = 0.8-70 μm) confirmed the 3D printed devices generated bulk acoustic waves (BAWs) capable of size-selective manipulation, trapping, and separation of suspended particles in droplets and microchannels. Flow visualization studies in a continuous flow format showed suspended particles could be moved toward or away from the walls of microfluidic channels based on selective actuation of in-plane or out-of-plane PZT chips. This work suggests additive manufacturing potentially provides new opportunities for the design and fabrication of acoustofluidic and microfluidic devices.

Indexed as

AcousticsLab-On-A-Chip DevicesDimethylpolysiloxanesEquipment DesignMicro-Electrical-Mechanical SystemsPrinting, Three-DimensionalbaysilonDimethylpolysiloxanes

Identifiers

PMID29897358
PMCPMC6077993

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.