Evidence map›Paper›PMID 29892193›Full record

ArticleInternational journal of chronic obstructive pulmonary disease2018

Diversity of respiratory impedance based on quantitative computed tomography in patients with COPD.

Yosuke Wada, Yoshiaki Kitaguchi, Masanori Yasuo, Fumika Ueno, Satoshi Kawakami, Kiyoyasu Fukushima, Keisaku Fujimoto, Masayuki Hanaoka

Abstract read
In one paragraph

Article in International journal of chronic obstructive pulmonary disease, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yosuke WadaFirst Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
Yoshiaki KitaguchiFirst Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
Masanori YasuoFirst Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
Fumika UenoFirst Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
Satoshi KawakamiDepartment of Radiology, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.
Kiyoyasu FukushimaDepartment of Respiratory Medicine, Japanese Red Cross Nagasaki Genbaku Isahaya Hospital, Isahaya, Nagasaki, Japan.
Keisaku FujimotoDepartments of Clinical Laboratory Sciences, Shinshu University School of Health Sciences, Matsumoto, Nagano, Japan.
Masayuki HanaokaFirst Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, Nagano, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: This study was conducted in order to investigate the diversity of respiratory physiology, including the respiratory impedance and reversibility of airway obstruction, based on quantitative computed tomography (CT) in patients with COPD. Patients and methods: Medical records of 174 stable COPD patients were retrospectively reviewed to obtain the patients' clinical data, including the pulmonary function and imaging data. According to the software-based quantification of the degree of emphysema and airway wall thickness, the patients were classified into the "normal by CT" phenotype, the airway-dominant phenotype, the emphysema-dominant phenotype, and the mixed phenotype. The pulmonary function, including the respiratory impedance evaluated by using the forced oscillation technique (FOT) and the reversibility of airway obstruction in response to inhaled short-acting β Results: The respiratory system resistance at 5 and 20 Hz (R5 and R20) was significantly higher, and the respiratory system reactance at 5 Hz (X5) was significantly more negative in the airway-dominant and mixed phenotypes than in the other phenotypes. The within-breath changes of X5 (ΔX5) were significantly greater in the mixed phenotype than in the "normal by CT" and emphysema-dominant phenotypes. The FOT parameters (R5, R20, and X5) were significantly correlated with indices of the degree of airway wall thickness and significantly but weakly correlated with the reversibility of airway obstruction. There was no significant correlation between the FOT parameters (R5, R20, and X5) and the degree of emphysema. Conclusion: There is a diversity of respiratory physiology, including the respiratory impedance and reversibility of airway obstruction, based on quantitative CT in patients with COPD. The FOT measurements may reflect the degree of airway disease and aid in detecting airway remodeling in patients with COPD.

Indexed as

Adrenergic beta-2 Receptor AgonistsAgedAirway ResistanceElectric ImpedanceFemaleForced Expiratory VolumeHumansMalePhenotypePulmonary Disease, Chronic ObstructivePulmonary EmphysemaRespiratory Function TestsRetrospective StudiesTomography, X-Ray ComputedVital CapacityAdrenergic beta-2 Receptor AgonistsAWT-Pi10FOTMostGraphrespiratory impedance

Identifiers

PMID29892193
PMCPMC5993027

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.