Evidence map›Paper›PMID 29890988›Full record

ArticleBiomedical engineering online2018

Automatic hand phantom map generation and detection using decomposition support vector machines.

Huaiqi Huang, Claudio Bruschini, Christian Antfolk, Christian Enz, Tao Li, Jörn Justiz, Volker M Koch

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Huaiqi HuangBME Lab, Institute for Human Centered Engineering, Bern University of Applied Sciences, Quellgasse 21, 2502, Biel, Switzerland. huaiqi.huang@epfl.ch.ORCID http://orcid.org/0000-0003-2075-0717
Claudio BruschiniIntegrated Circuits Laboratory (ICLAB), École Polytechnique Fédérale de Lausanne (EPFL), Rue de la Maladiére 71b, 2002, Neuchâtel, Switzerland.ORCID http://orcid.org/0000-0002-6636-6596
Christian AntfolkBiomedical Engineering, Lund University, Ole Römers väg 3, 22100, Lund, Sweden.
Christian EnzIntegrated Circuits Laboratory (ICLAB), École Polytechnique Fédérale de Lausanne (EPFL), Rue de la Maladiére 71b, 2002, Neuchâtel, Switzerland.
Tao LiBME Lab, Institute for Human Centered Engineering, Bern University of Applied Sciences, Quellgasse 21, 2502, Biel, Switzerland.
Jörn JustizBME Lab, Institute for Human Centered Engineering, Bern University of Applied Sciences, Quellgasse 21, 2502, Biel, Switzerland.
Volker M KochBME Lab, Institute for Human Centered Engineering, Bern University of Applied Sciences, Quellgasse 21, 2502, Biel, Switzerland.
Bern University of Applied Sciences · CHÉcole Polytechnique Fédérale de Lausanne · CHLund University · SE

Funding

Forskningsrådet för Arbetsliv och Socialvetenskap 637-2013-444Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung 20NA21 143070
6 · The paper itself

Abstract

backgroundThere is a need for providing sensory feedback for myoelectric prosthesis users. Providing tactile feedback can improve object manipulation abilities, enhance the perceptual embodiment of myoelectric prostheses and help reduce phantom limb pain. Many amputees have referred sensation from their missing hand on their residual limbs (phantom maps). This skin area can serve as a target for providing amputees with non-invasive tactile sensory feedback. One of the challenges of providing sensory feedback on the phantom map is to define the accurate boundary of each phantom digit because the phantom map distribution varies from person to person.

methodsIn this paper, automatic phantom map detection methods based on four decomposition support vector machine algorithms and three sampling methods are proposed, complemented by fuzzy logic and active learning strategies. The algorithms and methods are tested on two databases: the first one includes 400 generated phantom maps, whereby the phantom map generation algorithm was based on our observation of the phantom maps to ensure smooth phantom digit edges, variety, and representativeness. The second database includes five reported phantom map images and transformations thereof. The accuracy and training/ classification time of each algorithm using a dense stimulation array (with 100 [Formula: see text] 100 actuators) and two coarse stimulation arrays (with 3 [Formula: see text] 5 and 4 [Formula: see text] 6 actuators) are presented and compared.

resultsBoth generated and reported phantom map images share the same trends. Majority-pooling sampling effectively increases the training size, albeit introducing some noise, and thus produces the smallest error rates among the three proposed sampling methods. For different decomposition architectures, one-vs-one reduces unclassified regions and in general has higher classification accuracy than the other architectures. By introducing fuzzy logic to bias the penalty parameter, the influence of pooling-induced noise is reduced. Moreover, active learning with different strategies was also tested and shown to improve the accuracy by introducing more representative training samples. Overall, dense arrays employing one-vs-one fuzzy support vector machines with majority-pooling sampling have the smallest average absolute error rate (8.78% for generated phantom maps and 11.5% for reported and transformed phantom map images). The detection accuracy of coarse arrays was found to be significantly lower than for dense array.

conclusionsThe results demonstrate the effectiveness of support vector machines using a dense array in detecting refined phantom map shapes, whereas coarse arrays are unsuitable for this task. We therefore propose a two-step approach, using first a non-wearable dense array to detect an accurate phantom map shape, then to apply a wearable coarse stimulation array customized according to the detection results. The proposed methodology can be used as a tool for helping haptic feedback designers and for tracking the evolvement of phantom maps.

Indexed as

HandPhantoms, ImagingSupport Vector MachineAutomationDatabases, FactualFuzzy LogicHumansActive learningHand amputeeMachine learningPhantom mapSensory feedbackSupport vector machines

Identifiers

PMID29890988
PMCPMC5996576
OpenAlexW2808396257

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390