Evidence map›Paper›PMID 29888772›Full record

ArticlePhysical chemistry chemical physics : PCCP2018

X-ray-induced sample damage at the Mn L-edge: a case study for soft X-ray spectroscopy of transition metal complexes in solution.

Markus Kubin, Jan Kern, Meiyuan Guo, Erik Källman, Rolf Mitzner, Vittal K Yachandra, Marcus Lundberg, Junko Yano, Philippe Wernet

Abstract read
In one paragraph

Article in Physical chemistry chemical physics : PCCP, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Variability in X-ray induced effects in [Rh(COD)Cl]Physical chemistry chemical physics : PCCP · 2022
    Article
  4. Article
  5. Effects of x-ray free-electron laser pulse intensity on the Mn KStructural dynamics (Melville, N.Y.) · 2021
    Article
  6. Article
  7. Article
  8. Article
  9. Chemical interactions and dynamics with femtosecond X-ray spectroscopy and the role of X-ray free-electron lasers.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2019
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Markus KubinInstitute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin, Germany. wernet@helmholtz-berlin.de.
Jan Kern
Meiyuan Guo
Erik Källman
Rolf Mitzner
Vittal K Yachandra
Marcus Lundberg
Junko Yano
Philippe Wernet

Funding

Taking Snapshots of the Water-Oxidation Reaction by the Mn4Ca Oxygen-Evolving Complex Using X-ray Crystallography and SpectroscopyR01GM055302 · NIGMS · UNIVERSITY OF CALIF-LAWRENC BERKELEY LAB · PI YACHANDRA, VITTAL · 1997 to 2022
$9.1M
Biological Spectroscopy and Crystallography Using an X-ray Free Electron Laser - Supplemental EquipmentR01GM110501 · NIGMS · UNIVERSITY OF CALIF-LAWRENC BERKELEY LAB · PI Junko Yano · 2014 to 2026
$4.8M
High throughput sample delivery method for time resolved studies of enzyme reactions with X-ray and complementary techniquesR01GM126289 · NIGMS · UNIVERSITY OF CALIF-LAWRENC BERKELEY LAB · PI KERN, JAN F · 2017 to 2025
$4.6M
Structure and Function of the Mn Oxygen-Evolving ComplexR56GM055302 · NIGMS · UNIVERSITY OF CALIF-LAWRENC BERKELEY LAB · PI YACHANDRA, VITTAL · 2009 to 2009
$530k
NIGMS NIH HHS R01 GM055302NIGMS NIH HHS R01 GM110501NIGMS NIH HHS R01 GM126289NIGMS NIH HHS R56 GM055302
6 · The paper itself

Abstract

X-ray induced sample damage can impede electronic and structural investigations of radiation-sensitive samples studied with X-rays. Here we quantify dose-dependent sample damage to the prototypical MnIII(acac)3 complex in solution and at room temperature for the soft X-ray range, using X-ray absorption spectroscopy at the Mn L-edge. We observe the appearance of a reduced MnII species as the X-ray dose is increased. We find a half-damage dose of 1.6 MGy and quantify a spectroscopically tolerable dose on the order of 0.3 MGy (1 Gy = 1 J kg-1), where 90% of MnIII(acac)3 are intact. Our dose-limit is around one order of magnitude lower than the Henderson limit (half-damage dose of 20 MGy) which is commonly employed for protein crystallography with hard X-rays. It is comparable, however, to the dose-limits obtained for collecting un-damaged Mn K-edge spectra of the photosystem II protein, using hard X-rays. The dose-dependent reduction of MnIII observed here for solution samples occurs at a dose limit that is two to four orders of magnitude smaller than the dose limits previously reported for soft X-ray spectroscopy of iron samples in the solid phase. We compare our measured to calculated spectra from ab initio restricted active space (RAS) theory and discuss possible mechanisms for the observed dose-dependent damage of MnIII(acac)3 in solution. On the basis of our results, we assess the influence of sample damage in other experimental studies with soft X-rays from storage-ring synchrotron radiation sources and X-ray free-electron lasers.

Identifiers

PMID29888772
PMCPMC6011208

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.