Evidence map›Paper›PMID 29881844›Full record

ArticleLab on a chip2018

A pumpless body-on-a-chip model using a primary culture of human intestinal cells and a 3D culture of liver cells.

Huanhuan Joyce Chen, Paula Miller, Michael L Shuler

Open access · greenAbstract read
In one paragraph

Article in Lab on a chip, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 52 papers.

0numbers the graph read from it
0cells of the map it votes in
52citing papers in PubMed
6.1field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

52 citing papers in PubMed, 110 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Research Progress on Neural Cell Culture Systems.Current neuropharmacology · 2025
    Review
  12. Intestinal organ chips for disease modelling and personalized medicine.Nature reviews. Gastroenterology & hepatology · 2024
    Review
  13. Review
  14. Standard: human intestine-on-a-chip.Cell regeneration (London, England) · 2024
    Article
  15. Review
  16. Review
  17. Review
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 2 countries.

Huanhuan Joyce ChenDepartment of Biomedical Engineering, 115 Weill Hall, Cornell University, USA. mls50@cornell.edu.
Paula Miller
Michael L Shuler
Cornell University · US

Funding

Populating MPS database with data from multi-organ, human-on-a-chip microphysiological systemsR44TR001326 · NCATS · HESPEROS, LLC · PI HICKMAN, JAMES J, SHULER, MICHAEL L · 2016 to 2021
$6.5M
An organotypic model recapitulating colon cancer microenvironment and metastasisU01CA214300 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI HUANG, EMINA HUI-NA, SHEN, XILING · 2017 to 2021
$3.1M
Microphysiologial systems and low cost microfluidic platform with analyticsUH2TR000516 · NCATS · CORNELL UNIVERSITY · PI HICKMAN, JAMES J, SHULER, MICHAEL L · 2012 to 2014
$2.9M
Colorado Clinical and Translational Science Institute (KL2)KL2TR000156 · NCATS · UNIVERSITY OF COLORADO DENVER · PI SOKOL, RONALD J. · 2012 to 2013
$521k
NCATS NIH HHS KL2 TR000156NCATS NIH HHS R44 TR001326NCATS NIH HHS UH2 TR000516
6 · The paper itself

Abstract

We describe an expanded modular gastrointestinal (GI) tract-liver system by co-culture of primary human intestinal epithelial cells (hIECs) and 3D liver mimic. The two organ body-on-chip design consisted of GI and liver tissue compartments that were connected by fluidic medium flow driven via gravity. The hIECs and HepG2 C3A liver cells in the co-culture system maintained high viability for at least 14 days in which hIECs differentiated into major cell types found in native human intestinal epithelium and the HepG2 C3A cells cultured on 3D polymer scaffold formed a liver micro-lobe like structure. Moreover, the hIECs formed a monolayer on polycarbonate membranes with a tight junction and authentic TEER values of approximately 250 Ω cm2 for the native gut. The hIEC permeability was compared to a conventional permeability model using Caco-2 cell response for drug absorption by measuring the uptake of propranolol, mannitol and caffeine. Metabolic rates (urea or albumin production) of the cells in the co-culture GI-liver system were comparable to those of HepG2 C3A cells in a single-organ fluidic culture system, while induced CYP activities were significantly increased in the co-culture GI tract-liver system compared to the single-organ fluidic culture system. These results demonstrated potential of the low-cost microphysiological GI-liver model for preclinical studies to predict human response.

Indexed as

Lab-On-A-Chip DevicesAlbuminsCaco-2 CellsCoculture TechniquesHep G2 CellsHumansIntestinal MucosaLiverUreaAlbuminsUrea

Identifiers

PMID29881844
PMCPMC6039263
OpenAlexW2805769800

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.