Evidence map›Paper›PMID 29871834›Full record

ArticleThe Journal of arthroplasty2018

What Is the Incidence of Cobalt-Chromium Damage Modes on the Bearing Surface of Contemporary Femoral Component Designs for Total Knee Arthroplasty?

Christina M Arnholt, Daniel W MacDonald, Gregg R Klein, Harold E Cates, Clare M Rimnac, Steven M Kurtz, Implant Research Center Writing Committee, Sevi Kocagoz, Antonia F Chen

Abstract read
In one paragraph

Article in The Journal of arthroplasty, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Mixed material wear particle isolation from periprosthetic tissue surrounding total joint replacements.Journal of biomedical materials research. Part B, Applied biomaterials · 2022
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Christina M ArnholtImplant Research Center, Drexel University, Philadelphia, Pennsylvania.
Daniel W MacDonaldImplant Research Center, Drexel University, Philadelphia, Pennsylvania.
Gregg R KleinHartzband Center for Hip & Knee Replacement, Paramus, New Jersey.
Harold E CatesTennessee Orthopedic Clinics, Knoxville, Tennessee.
Clare M RimnacDepartment of Mechanical and Aerospace Engineering and the Center for the Evaluation of Implant Performance, Case Western Reserve University, Cleveland, Ohio.
Steven M KurtzImplant Research Center, Drexel University, Philadelphia, Pennsylvania; Exponent, Inc., Biomedical Engineering Practice, Philadelphia, Pennsylvania.
Implant Research Center Writing Committee
Sevi KocagozImplant Research Center, Drexel University, Philadelphia, Pennsylvania.
Antonia F ChenBrigham and Women's Hospital, Department of Orthopaedics, Harvard Medical School, Boston, Massachusetts.

Funding

MECHANISMS &PERFORMANCE OF TRACEABLE UHMWPE IMPLANTSR01AR047904 · NIAMS · DREXEL UNIVERSITY · PI KURTZ, STEVEN MICHAEL · 2001 to 2015
$6.1M
NIAMS NIH HHS R01 AR047904
6 · The paper itself

Abstract

backgroundThe purpose of this study was to determine the incidence of metal release in contemporary total knee arthroplasty and the patient-related factors associated with this release.

methodsIn total, 256 retrieved cobalt-chromium femoral components were collected through a multi-institutional orthopedic implant retrieval program (implanted: 1-15 years). Implants were mainly revised for loosening (84/256), instability (62/256), and infection (46/256). Third-body damage was assessed using a semiquantitative scoring method. Microscale electro-corrosion damage (MECD) was evaluated using digital optical microscopy. Radii of curvature were measured from representative components to calculate anterior-posterior and medial-lateral ratios. Femoral component surface roughness was measured using a white light interferometer. Using a multivariable linear model, associations between damage score, implant, and patient factors were tested. Spearman's ρ correlation tests were performed to determine the association between roughness measurements and damage score.

resultsMild to severe damage was observed in 52% (134/256) of the components. In the multivariable linear model, anterior-posterior ratio (β = -8.07; P < .001), loosening (β = -0.52; P = .006), and patient weight (β = 0.01; P = .007) were associated with damage score. Suspected MECD damage was observed in 82% (209/256) of components. The R

conclusionThe findings of this retrieval study support that similar damage mechanisms exist in contemporary and long-term total knee arthroplasty devices. Additionally, we observed associations between loosening, anterior-posterior conformity, and patient weight with increased surface damage.

Indexed as

Chromium AlloysAdultAgedAged, 80 and overArthroplasty, Replacement, KneeChromiumCobaltCorrosionFemaleFemurHumansKnee ProsthesisMaleMiddle AgedProsthesis DesignProsthesis FailureChromiumChromium AlloysCobaltbearing surface damagecobalt-chromiumimplant conformitymicro-scale electro-corrosion damagetotal knee arthroplasty

Identifiers

PMID29871834
PMCPMC6146069

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked