Evidence map›Paper›PMID 29871656›Full record

ArticleRadiation oncology (London, England)2018

Evaluation of gold fiducial marker manual localisation for magnetic resonance-only prostate radiotherapy.

Matteo Maspero, Peter R Seevinck, Nicole J W Willems, Gonda G Sikkes, Geja J de Kogel, Hans C J de Boer, Jochem R N van der Voort van Zyp, Cornelis A T van den Berg

Abstract readEvaluation Study
In one paragraph

Article in Radiation oncology (London, England), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Trial
  2. Article
  3. QSM Throughout the Body.Journal of magnetic resonance imaging : JMRI · 2023
    Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Matteo MasperoUniversitair Medisch Centrum Utrecht, Heidelberglaan 100, Utrecht, 3508 GA, The Netherlands. m.maspero@umcutrecht.nl.
Peter R SeevinckUniversitair Medisch Centrum Utrecht, Heidelberglaan 100, Utrecht, 3508 GA, The Netherlands.
Nicole J W WillemsUniversitair Medisch Centrum Utrecht, Heidelberglaan 100, Utrecht, 3508 GA, The Netherlands.
Gonda G SikkesUniversitair Medisch Centrum Utrecht, Heidelberglaan 100, Utrecht, 3508 GA, The Netherlands.
Geja J de KogelUniversitair Medisch Centrum Utrecht, Heidelberglaan 100, Utrecht, 3508 GA, The Netherlands.
Hans C J de BoerUniversitair Medisch Centrum Utrecht, Heidelberglaan 100, Utrecht, 3508 GA, The Netherlands.
Jochem R N van der Voort van ZypUniversitair Medisch Centrum Utrecht, Heidelberglaan 100, Utrecht, 3508 GA, The Netherlands.
Cornelis A T van den BergUniversitair Medisch Centrum Utrecht, Heidelberglaan 100, Utrecht, 3508 GA, The Netherlands.

Funding

ZonMw 1040030
6 · The paper itself

Abstract

backgroundThe use of intraprostatic gold fiducial markers (FMs) ensures highly accurate and precise image-guided radiation therapy for patients diagnosed with prostate cancer thanks to the ease of localising FMs on photon-based imaging, like Computed Tomography (CT) images. Recently, Magnetic Resonance (MR)-only radiotherapy has been proposed to simplify the workflow and reduce possible systematic uncertainties. A critical, determining factor in the accuracy of such an MR-only simulation will be accurate FM localisation using solely MR images. PURPOSE: The aim of this study is to evaluate the performances of manual MR-based FM localisation within a clinical environment.

methodsWe designed a study in which 5 clinically involved radiation therapy technicians (RTTs) independently localised the gold FMs implanted in 16 prostate cancer patients in two scenarios: employing a single MR sequence or a combination of sequences. Inter-observer precision and accuracy were assessed for the two scenarios for localisation in terms of 95% limit of agreement on single FMs (LoA)/ centre of mass (LoA

resultsThe number of precisely located FMs (LoA <2 mm) increased from 38/48 to 45/48 FMs when localisation was performed using multiple sequences instead of single one. When performing localisation on multiple sequences, imprecise localisation of the FMs (3/48 FMs) occurred for 1/3 implanted FMs in three different patients. In terms of precision, we obtained LoA

conclusionsFor both the investigated scenarios, the results indicate that when FM classification was correct, the precision and accuracy are high and comparable to CT-based FM localisation. We found that use of multiple sequences led to better localisation performances compared with the use of single sequence. However, we observed that, due to the presence of calcification and motion, the risk of mislocated patient positioning is still too high to allow the sole use of manual FM localisation. Finally, strategies to possibly overcome the current challenges were proposed.

Indexed as

Fiducial MarkersGoldMagnetic Resonance ImagingAgedAged, 80 and overHumansMaleMiddle AgedObserver VariationPatient PositioningProstateProstatic NeoplasmsRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedReproducibility of ResultsTomography, X-Ray ComputedGoldAccuracyFiducial marker localizationMagnetic resonance imagingManual detectionMR-only treatment planningPrecisionPre-treatment positioningRadiotherapy treatment planning

Identifiers

PMID29871656
PMCPMC5989467

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.