Observational studyAmerican journal of obstetrics and gynecology2018
Six-month expulsion of postplacental copper intrauterine devices placed after vaginal delivery.
Observational study in American journal of obstetrics and gynecology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 28 citations in OpenAlex.
- Utilisation, effectiveness, and safety of immediate postpartum intrauterine device insertion: a systematic literature review.BMJ sexual & reproductive health · 2023Pooled it
- Expulsion of intrauterine devices after postpartum placement by timing of placement, delivery type, and intrauterine device type: a systematic review and meta-analysis.American journal of obstetrics and gynecology · 2020Pooled it
- Manual versus forceps postplacental IUD insertion after vaginal delivery: A randomized clinical trial.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2026Trial
- Effectiveness, safety and overall satisfaction of early postpartum placement of hormonal IUD compared with standard procedure: An open-label, randomized, multicenter study.Acta obstetricia et gynecologica Scandinavica · 2022Trial
- Risk factors of uterine perforation when using contraceptive intrauterine devices.BMC women's health · 2024Article
- Immediate Postpartum Insertion of Copper Intrauterine Device in a Brazilian University Hospital: Expulsion and Continuation Rates.Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia · 2023Article
- Article
- Assessment of a Novel Fixation Method of a Frameless Intrauterine Contraceptive Device Inserted during Cesarean Delivery as a Means of Preventing Displacements and Expulsions: A Prospective Observational Study.Life (Basel, Switzerland) · 2022Article
- Postplacental Insertion of Levonorgestrel Intrauterine System Versus Copper Intrauterine Device: A Prospective Study.Journal of obstetrics and gynaecology of India · 2021Article
- Risk factors for postpartum intrauterine device expulsion among women delivering at a tertiary Hospital in Uganda: a prospective cohort study.Contraception and reproductive medicine · 2021Article
- Expulsion rate of intrauterine device: mediate vs. immediate puerperium periodJournal of the Turkish German Gynecological Association · 2020Article
- Ultrasound assessment of postplacental copper intrauterine device position 6 months after placement during cesarean delivery.Contraception: X · 2020Article
- A Decision Analysis Model of 1-Year Effectiveness of Intended Postplacental Compared With Intended Delayed Postpartum Intrauterine Device Insertion.Obstetrics and gynecology · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundImmediate placement of an intrauterine device after vaginal delivery is safe and convenient, but longitudinal data describing clinical outcomes have been limited.
objectiveWe sought to determine the proportion of TCu380A (copper) intrauterine devices expelled, partially expelled, malpositioned, and retained, as well as contraceptive use by 6 months postpartum, and determine risk factors for expulsion and partial expulsion. STUDY
designIn this prospective, observational study, women who received a postplacental TCu380A intrauterine device at vaginal delivery were enrolled postpartum. Participants returned for clinical follow-up at 6 weeks, and for a research visit with a pelvic exam and ultrasound at 6 months. We recorded intrauterine device outcomes and 6-month contraceptive use. Partial expulsion was defined as an intrauterine device protruding from the external cervical os, or a transvaginal ultrasound showing the distal end of the intrauterine device below the internal os of the cervix. Multinomial logistic regression models identified risk factors associated with expulsion and partial expulsion by 6 months. The area under the receiver operating characteristics curve was used to assess the ability of a string check to predict the correct placement of a postplacental intrauterine device. The primary outcome was the proportion of intrauterine devices expelled at 6 months.
resultsWe enrolled 200 women. Of 162 participants with follow-up data at 6 months, 13 (8.0%; 95% confidence interval, 4.7-13.4%) experienced complete expulsion and 26 (16.0%; 95% confidence interval, 11.1-22.6%) partial expulsion. Of 25 malpositioned intrauterine devices (15.4%; 95% confidence interval, 10.2-21.9%), 14 were not at the fundus (8.6%; 95% confidence interval, 5.2-14.1%) and 11 were rotated within the uterus (6.8%; 95% confidence interval, 3.8-11.9%). Multinomial logistic regression modeling indicated that higher parity (odds ratio, 2.05; 95% confidence interval, 1.21-3.50; P = .008) was associated with expulsion. Provider specialty (obstetrics vs family medicine; odds ratio, 5.31; 95% confidence interval, 1.20-23.59; P = .03) and gestational weight gain (normal vs excess; odds ratio, 9.12; 95% confidence interval, 1.90-43.82; P = .004) were associated with partial expulsion. Long-acting reversible contraceptive method use at 6 months was 80.9% (95% confidence interval, 74.0-86.6%). At 6 weeks postpartum, 35 of 149 (23.5%; 95% confidence interval, 16.9-31.1%) participants had no intrauterine device strings visible. Sensitivity of a string check to detect an incorrectly positioned intrauterine device was 36.2%, and specificity of the string check to predict a correctly positioned intrauterine device was 84.5%. This corresponds to an area under the receiver operating characteristics curve of 0.5.
conclusionThis prospective assessment of postplacental TCu380A intrauterine device placement, with ultrasound to confirm device position, finds a complete intrauterine device expulsion proportion of 8.0% at 6 months. The association of increasing parity with expulsion is consistent with prior research. The clinical significance of covariates associated with partial expulsion (provider specialty and gestational weight gain) is unclear. Due to the observational study design, any associations cannot imply causality. The proportion of partially expelled and malpositioned intrauterine devices was high, and the area under the receiver operating characteristics curve of 0.5 indicates that a string check is a poor test for assessing device position. Women considering a postplacental intrauterine device should be counseled about the risk of position abnormalities, as well as the possibility of nonvisible strings, which may complicate clinical follow-up. The clinical significance of intrauterine device position abnormalities is unknown; future research should evaluate the influence of malposition and partial expulsion on contraceptive effectiveness and side effects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.