Evidence map›Paper›PMID 29870737›Full record

Observational studyAmerican journal of obstetrics and gynecology2018

Six-month expulsion of postplacental copper intrauterine devices placed after vaginal delivery.

Elizabeth P Gurney, Sarita Sonalkar, Arden McAllister, Mary D Sammel, Courtney A Schreiber

Abstract readObservational Study
In one paragraph

Observational study in American journal of obstetrics and gynecology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 2 pooled it
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 28 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Manual versus forceps postplacental IUD insertion after vaginal delivery: A randomized clinical trial.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2026
    Trial
  4. Trial
  5. Article
  6. Immediate Postpartum Insertion of Copper Intrauterine Device in a Brazilian University Hospital: Expulsion and Continuation Rates.Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia · 2023
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Expulsion rate of intrauterine device: mediate vs. immediate puerperium periodJournal of the Turkish German Gynecological Association · 2020
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Elizabeth P GurneyDepartment of Obstetrics and Gynecology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA; Department of Obstetrics and Gynecology, Einstein Medical Center Philadelphia, Philadelphia, PA. Electronic address: gurneyel@einstein.edu.
Sarita SonalkarDepartment of Obstetrics and Gynecology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA.
Arden McAllisterDepartment of Obstetrics and Gynecology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA.
Mary D SammelDepartment of Biostatistics, Epidemiology, and Informatics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA.
Courtney A SchreiberDepartment of Obstetrics and Gynecology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA.
University of Pennsylvania · USEinstein Medical Center Philadelphia · US

Funding

WOMENS REPRODUCTIVE HEALTH RESEARCH CAREER DEVELOPMENTK12HD001265 · NICHD · UNIVERSITY OF PENNSYLVANIA · PI Elizabeth A Howell · 1998 to 2026
$7.5M
NICHD NIH HHS K12 HD001265
6 · The paper itself

Abstract

backgroundImmediate placement of an intrauterine device after vaginal delivery is safe and convenient, but longitudinal data describing clinical outcomes have been limited.

objectiveWe sought to determine the proportion of TCu380A (copper) intrauterine devices expelled, partially expelled, malpositioned, and retained, as well as contraceptive use by 6 months postpartum, and determine risk factors for expulsion and partial expulsion. STUDY

designIn this prospective, observational study, women who received a postplacental TCu380A intrauterine device at vaginal delivery were enrolled postpartum. Participants returned for clinical follow-up at 6 weeks, and for a research visit with a pelvic exam and ultrasound at 6 months. We recorded intrauterine device outcomes and 6-month contraceptive use. Partial expulsion was defined as an intrauterine device protruding from the external cervical os, or a transvaginal ultrasound showing the distal end of the intrauterine device below the internal os of the cervix. Multinomial logistic regression models identified risk factors associated with expulsion and partial expulsion by 6 months. The area under the receiver operating characteristics curve was used to assess the ability of a string check to predict the correct placement of a postplacental intrauterine device. The primary outcome was the proportion of intrauterine devices expelled at 6 months.

resultsWe enrolled 200 women. Of 162 participants with follow-up data at 6 months, 13 (8.0%; 95% confidence interval, 4.7-13.4%) experienced complete expulsion and 26 (16.0%; 95% confidence interval, 11.1-22.6%) partial expulsion. Of 25 malpositioned intrauterine devices (15.4%; 95% confidence interval, 10.2-21.9%), 14 were not at the fundus (8.6%; 95% confidence interval, 5.2-14.1%) and 11 were rotated within the uterus (6.8%; 95% confidence interval, 3.8-11.9%). Multinomial logistic regression modeling indicated that higher parity (odds ratio, 2.05; 95% confidence interval, 1.21-3.50; P = .008) was associated with expulsion. Provider specialty (obstetrics vs family medicine; odds ratio, 5.31; 95% confidence interval, 1.20-23.59; P = .03) and gestational weight gain (normal vs excess; odds ratio, 9.12; 95% confidence interval, 1.90-43.82; P = .004) were associated with partial expulsion. Long-acting reversible contraceptive method use at 6 months was 80.9% (95% confidence interval, 74.0-86.6%). At 6 weeks postpartum, 35 of 149 (23.5%; 95% confidence interval, 16.9-31.1%) participants had no intrauterine device strings visible. Sensitivity of a string check to detect an incorrectly positioned intrauterine device was 36.2%, and specificity of the string check to predict a correctly positioned intrauterine device was 84.5%. This corresponds to an area under the receiver operating characteristics curve of 0.5.

conclusionThis prospective assessment of postplacental TCu380A intrauterine device placement, with ultrasound to confirm device position, finds a complete intrauterine device expulsion proportion of 8.0% at 6 months. The association of increasing parity with expulsion is consistent with prior research. The clinical significance of covariates associated with partial expulsion (provider specialty and gestational weight gain) is unclear. Due to the observational study design, any associations cannot imply causality. The proportion of partially expelled and malpositioned intrauterine devices was high, and the area under the receiver operating characteristics curve of 0.5 indicates that a string check is a poor test for assessing device position. Women considering a postplacental intrauterine device should be counseled about the risk of position abnormalities, as well as the possibility of nonvisible strings, which may complicate clinical follow-up. The clinical significance of intrauterine device position abnormalities is unknown; future research should evaluate the influence of malposition and partial expulsion on contraceptive effectiveness and side effects.

Indexed as

Delivery, ObstetricGestational Weight GainIntrauterine Device ExpulsionIntrauterine Device MigrationIntrauterine Devices, CopperPostnatal CareAdultArea Under CurveContraceptive AgentsFemaleHumansLogistic ModelsLongitudinal StudiesObstetricsPatient SatisfactionPhysicians, FamilyContraceptive Agentscopper intrauterine deviceintrauterine deviceintrauterine device complicationintrauterine device expulsionintrauterine device retentionlong-acting reversible contraceptionpostpartum contraceptionpostpartum intrauterine devicepostplacental intrauterine deviceTCu380A intrauterine devicevaginal delivery

Identifiers

PMID29870737
PMCPMC6125156
OpenAlexW2805971679

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.