Evidence map›Paper›PMID 29869759›Full record

ArticleThe international journal of cardiovascular imaging2018

Semi-automatic CT-angiography based evaluation of the aortic annulus in patients prior to TAVR: interchangeability with manual measurements.

Dominik Zinsser, Alena B Baumann, Katharina Stella Winter, Fabian Bamberg, Philipp Lange, Konstantin Nikolaou, Maximilian Reiser, Christian Kupatt, Thomas Kröncke, Florian Schwarz

Abstract read
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Dominik ZinsserAbteilung für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Tübingen, Tübingen, Germany.
Alena B BaumannKlinik und Poliklinik für Radiologie, LMU München, Munich, Germany.
Katharina Stella WinterKlinik und Poliklinik für Radiologie, LMU München, Munich, Germany.
Fabian BambergAbteilung für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Tübingen, Tübingen, Germany.
Philipp LangeMedizinische Klinik und Poliklinik I, LMU München, Munich, Germany.
Konstantin NikolaouAbteilung für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Tübingen, Tübingen, Germany.
Maximilian ReiserKlinik und Poliklinik für Radiologie, LMU München, Munich, Germany.
Christian KupattKlinik und Poliklinik für Innere Medizin I, TU München, Munich, Germany.
Thomas KrönckeKlinik für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Klinikum Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany.
Florian SchwarzKlinik für Diagnostische und Interventionelle Radiologie und Neuroradiologie, Klinikum Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany. Florian.Schwarz@klinikum-augsburg.de.ORCID http://orcid.org/0000-0001-9889-5153

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To compare a semi-automatic software tool for the measurement of aortic annulus dimensions with manual measurements by expert readers and to analyze whether and to what extent interchangeability exists between semi-automatic and manual measurements. We retrospectively included 374 consecutive patients with high-grade aortic stenosis who had undergone CT-angiography of the heart prior to trans-catheter aortic valve replacement (TAVR). In independent analyses, two expert readers manually measured aortic annulus dimensions (long axis, short axis, circumference, area) as well as the distance of the coronary ostia from the annulus plane. A third independent reader performed annulus evaluation using a software tool for semi-automatic detection and measurement of the annulus plane. Intraclass correlation coefficients (ICC) and Bland-Altman analysis was used to compare both manual measurements as well as manual and semi-automatic measurements of annulus parameters. Using the respective measurements we simulated size selection for a Sapien XT transcatheter heart valve (THV). Interchangeability of methods was addressed by calculation of the estimated individual equivalence index γ. There was excellent agreement between both expert observers in manual measurements of the annulus with ICC's in the range 0.89-0.94 for all anatomic parameters. Similar high agreements were observed between semi-automatic and manual measurements, with ICC's in the range of 0.89-0.95. THV size recommendation based on manual versus semiautomatic measurements agreed in 80.7% of cases while agreement between both expert readers concerning THV size recommendation was 80.6%. Semi-automatic measurements of anatomic parameters of the aortic root show high agreement and interchangeability with manual measurements in CT-angiography prior to TAVR.

Indexed as

AgedAged, 80 and overAortic ValveAortic Valve StenosisAutomationComputed Tomography AngiographyFemaleHumansMalePredictive Value of TestsReproducibility of ResultsRetrospective StudiesTranscatheter Aortic Valve ReplacementAnnulus sizingAortic annulusTAVITAVRTrans-catheter aortic valve implantationTrans-catheter aortic valve replacementValve sizing

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.