Evidence map›Paper›PMID 29869186›Full record

ArticleEJNMMI physics2018

Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

Beverley F Holman, Vesna Cuplov, Lynn Millner, Raymond Endozo, Toby M Maher, Ashley M Groves, Brian F Hutton, Kris Thielemans

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Consensus Recommendations on the Use ofJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Beverley F HolmanInstitute of Nuclear Medicine, University College London, UCLH (T-5), Euston Road, London, NW1 2BU, UK. beverley.holman@nhs.net.
Vesna CuplovInstitute of Nuclear Medicine, University College London, UCLH (T-5), Euston Road, London, NW1 2BU, UK.
Lynn MillnerInstitute of Nuclear Medicine, University College London, UCLH (T-5), Euston Road, London, NW1 2BU, UK.
Raymond EndozoInstitute of Nuclear Medicine, University College London, UCLH (T-5), Euston Road, London, NW1 2BU, UK.
Toby M MaherNational Institute for Health Research Respiratory Biomedical Research Unit, Royal Brompton Hospital, Sydney St, London, SW3 6NP, UK.
Ashley M GrovesInstitute of Nuclear Medicine, University College London, UCLH (T-5), Euston Road, London, NW1 2BU, UK.
Brian F HuttonInstitute of Nuclear Medicine, University College London, UCLH (T-5), Euston Road, London, NW1 2BU, UK.
Kris ThielemansInstitute of Nuclear Medicine, University College London, UCLH (T-5), Euston Road, London, NW1 2BU, UK.
University College London · GBImperial College London · GB

Funding

Engineering and Physical Sciences Research Council EP/K0052781/1GlaxoSmithKline foundation STU100028576
6 · The paper itself

Abstract

backgroundMatched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic

resultsUsing XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections.

conclusionsUse of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

Indexed as

Attenuation correctionDensityDynamic PETLungPET/CTQuantitationRespiration

Identifiers

PMID29869186
PMCPMC5986691
OpenAlexW2805767895

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.