ArticleJournal of the American Society for Mass Spectrometry2018
Determining Energies and Cross Sections of Individual Ions Using Higher-Order Harmonics in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS).
Article in Journal of the American Society for Mass Spectrometry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed.
- Quantification of Intact MDa Poly(A)-Tailed and Non-Tailed mRNA Fractions with Charge Detection Mass Spectrometry.Analytical chemistry · 2026Article
- Accurate Sizing and Resolution of Nominal 200 nm Diameter Polystyrene Nanospheres With Charge Detection Mass Spectrometry.Small (Weinheim an der Bergstrasse, Germany) · 2026Article
- Adeno-associated virus serotype 9 structural heterogeneity and stability characterized by charge detection mass spectrometry.Molecular therapy. Methods & clinical development · 2025Article
- Article
- Charge Detection Mass Spectrometry Reveals Conformational Heterogeneity in Megadalton-Sized Monoclonal Antibody Aggregates.Journal of the American Chemical Society · 2024Article
- Article
- Ion emission from 1-10 MDa salt clusters: individual charge state resolution with charge detection mass spectrometry.The Analyst · 2024Article
- Combined Multiharmonic Frequency Analysis for Improved Dynamic Energy Measurements and Accuracy in Charge Detection Mass Spectrometry.Analytical chemistry · 2023Article
- Dynamics of Rayleigh Fission Processes in ∼100 nm Charged Aqueous Nanodrops.ACS central science · 2023Article
- Dynamic Energy Measurements in Charge Detection Mass Spectrometry Eliminate Adverse Effects of Ion-Ion Interactions.Analytical chemistry · 2023Article
- Accurate Sizing of Nanoparticles Using a High-Throughput Charge Detection Mass Spectrometer without Energy Selection.ACS nano · 2023Article
- Apodization Specific Fitting for Improved Resolution, Charge Measurement, and Data Analysis Speed in Charge Detection Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2022Article
- Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry.Analytical chemistry · 2022Article
- Approaches to Heterogeneity in Native Mass Spectrometry.Chemical reviews · 2022Review
- Direct observation of ion emission from charged aqueous nanodrops: effects on gaseous macromolecular charging.Chemical science · 2021Article
- Mass Spectrometry-Based Structural Virology.Analytical chemistry · 2021Review
- Native Mass Spectrometry of Membrane Proteins.Analytical chemistry · 2021Review
- Parallel Detection of Fundamental and Sixth Harmonic Signals Using an ICR Cell with Dipole and Sixth Harmonic Detectors.Journal of the American Society for Mass Spectrometry · 2020Article
- Enhanced Multiplexing in Fourier Transform Charge Detection Mass Spectrometry by Decoupling Ion Frequency from Mass to Charge Ratio.Journal of the American Society for Mass Spectrometry · 2019Article
- Effects of Individual Ion Energies on Charge Measurements in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS).Journal of the American Society for Mass Spectrometry · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
A general method for in situ measurements of the energy of individual ions trapped and weighed using charge detection mass spectrometry (CDMS) is described. Highly charged (> 300 e), individual polyethylene glycol (PEG) ions are trapped and oscillate within an electrostatic trap, producing a time domain signal. A segmented Fourier transform (FT) of this signal yields the temporal evolution of the fundamental and harmonic frequencies of ion motion throughout the 500-ms trap time. The ratio of the fundamental frequency and second harmonic (HAR) depends on the ion energy, which is an essential parameter for measuring ion mass in CDMS. This relationship is calibrated using simulated ion signals, and the calibration is compared to the HAR values measured for PEG ion signals where the ion energy was also determined using an independent method that requires that the ions be highly charged (> 300 e). The mean error of 0.6% between the two measurements indicates that the HAR method is an accurate means of ion energy determination that does not depend on ion size or charge. The HAR is determined dynamically over the entire trapping period, making it possible to observe the change in ion energy that takes place as solvent evaporates from the ion and collisions with background gas occur. This method makes it possible to measure mass changes, either from solvent evaporation or from molecular fragmentation (MS