Evidence map›Paper›PMID 29856834›Full record

ArticlePloS one2018

Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice.

Alois Philipp, Filip De Somer, Maik Foltan, Andre Bredthauer, Lars Krenkel, Florian Zeman, Karla Lehle

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 40 citations in OpenAlex.

  1. "In-Series" Continuous Renal Replacement Therapy and Therapeutic Plasma Exchange: Single-Center Retrospective Cohort, 2018-2022.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2026
    Article
  2. Article
  3. Incidence of neutrophil extracellular traps (NETs) in different membrane oxygenators: pilot in vitro experiments in commercially available coated membranes.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2025
    Article
  4. Article
  5. Antifouling Zwitterionic Polymer Coatings for Blood-Bearing Medical Devices.Langmuir : the ACS journal of surfaces and colloids · 2025
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Observational
  11. Article
  12. Article
  13. Article
  14. Determination of acute changes in new electrocardiography parameters during veno-venous extracorporeal membrane oxygenation support.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2020
    Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Alois PhilippDepartment of Cardiothoracic Surgery, University Hospital Regensburg, Regensburg, Germany.
Filip De SomerHeart Centre 5K12, University Hospital Ghent, Ghent, Belgium.
Maik FoltanDepartment of Cardiothoracic Surgery, University Hospital Regensburg, Regensburg, Germany.
Andre BredthauerDepartment of Anesthesiology, University Hospital Regensburg, Regensburg, Germany.
Lars KrenkelRegensburg Center of Biomedical Engineering, Ostbayerische Technische Hochschule, Regensburg, Germany.
Florian ZemanCenter for Clinical Studies, University Hospital Regensburg, Regensburg, Germany.
Karla LehleDepartment of Cardiothoracic Surgery, University Hospital Regensburg, Regensburg, Germany.ORCID 0000-0001-8856-4094
University Hospital Regensburg · DEGhent University Hospital · BEOTH Regensburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Over the past decade, veno-venous extracorporeal membrane oxygenation (vvECMO) has been increasingly utilized in respiratory failure in patients. This study presents our institution´s experience focusing on the life span of ECMO systems reflecting the performance of a particular system. A retrospective review of our ECMO database identified 461 adult patients undergoing vvECMO (2010-2017). Patients that required more than one system and survived the first exchange >24 hours (n = 139) were included. Life span until the first exchange and exchange criteria were analyzed for all systems (PLS, Cardiohelp HLS-set, both Maquet Cardiopulmonary, Rastatt, Germany; Deltastream/Hilite7000LT, iLA-activve, Xenios/NovaLung, Heilbronn, Germany; ECC.O5, LivaNova, Mirandola, Italy). At our ECMO center, the frequency of a system exchange was 30%. The median (IQR) life span was 9 (6-12) days. There was no difference regarding the different systems (p = 0.145 and p = 0.108, respectively). However, the Deltastream systems were exchanged more frequently due to elective technical complications (e. g. worsened gas transfer, development of coagulation disorder, increased bleedings complications) compared to the other exchanged systems (p = 0.013). In summary, the used ECMO systems are safe and effective for acute respiratory failure. There is no evidence for the usage of a specific system. Only the increased predictability of an imminent exchange preferred the usage of a Deltastream system. However, the decision to use a particular system should not depend solely on the possible criteria for an exchange.

Indexed as

Equipment FailureEquipment Failure AnalysisOxygenators, MembraneAdultExtracorporeal Membrane OxygenationFemaleHumansMalePrimary Health CareRespiratory Distress SyndromeRetrospective StudiesSeverity of Illness IndexTime Factors

Identifiers

PMID29856834
PMCPMC5983427
OpenAlexW2805799921

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.