Evidence map›Paper›PMID 29854338›Full record

ArticleClinics in orthopedic surgery2018

Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation.

Jin Hwan Ahn, Taeg Su Ko, Yong Seuk Lee, Hwa Jae Jeong, Jong Kuen Park

Abstract readComparative Study
In one paragraph

Article in Clinics in orthopedic surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Observational
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jin Hwan AhnDepartment of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
Taeg Su KoDepartment of Orthopedic Surgery, Barunbone Hospital, Seoul, Korea.
Yong Seuk LeeDepartment of Orthopedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Hwa Jae JeongDepartment of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
Jong Kuen ParkDepartment of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCortical suspensory femoral fixation is commonly performed for graft fixation to the femur in anterior cruciate ligament (ACL) reconstruction using hamstring tendons. The purpose of this study was to compare graft healing in the femoral tunnel, implant-related failure, and clinical results between fixed- and adjustable-length loop devices in outside-in ACL reconstruction.

methodsA total of 109 patients who underwent ACL reconstruction using the outside-in technique from December 2010 to July 2014 were included. For femoral graft fixation, a fixed-length loop device was used in 48 patients (fixed-loop group) and an adjustable-length loop device was used in 61 patients (adjustable-loop group). For evaluation of graft healing in the femoral tunnel, magnetic resonance imaging was performed at postoperative 6 months and the signal-to-noise ratios (SNRs) of the tendon graft and tendon-bone interface in the femoral bone tunnel were evaluated. The presence of synovial fluid was evaluated to determine loop lengthening at the femoral tunnel exit. Clinical results assessed using International Knee Documentation Committee score, Tegner-Lysholm Knee Scoring scale, and knee instability tests were compared between groups.

resultsThe SNRs of the tendon graft and tendon-bone interface were not statistically different between groups. The presence of synovial fluid at the femoral exit showed no statistical difference between groups. Clinical results were not significantly different between groups.

conclusionsThe adjustable-length loop device provided comparable graft healing, implant-related failure, and clinical results with the fixed-length loop device, allowing adaptation of the graft to the different tunnel lengths. Therefore, it could be effectively used with an adjustment according to the femoral tunnel length.

Indexed as

Internal FixatorsAnterior Cruciate LigamentAnterior Cruciate Ligament InjuriesAnterior Cruciate Ligament ReconstructionFemurHumansMagnetic Resonance ImagingTreatment OutcomeAnterior cruciate ligamentFemoral tunnelGraft healingSuspensory fixation device

Identifiers

PMID29854338
PMCPMC5964263

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.