Evidence map›Paper›PMID 29854336›Full record

ArticleClinics in orthopedic surgery2018

Supplementary Technique for Unstable Clavicle Shaft Fractures: Interfragmentary Wiring and Temporary Axial K-Wire Pinning.

Jinmyoung Dan, Byung-Kook Kim, Ho-Jae Lee, Tae-Ho Kim, Young-Gun Kim

Open access · diamondAbstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. [Effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in treatment of Cho typeZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Jinmyoung DanDepartment of Orthopedic Surgery, CHA Gumi Medical Center, CHA University School of Medicine, Gumi, Korea.
Byung-Kook KimDepartment of Orthopedic Surgery, CHA Gumi Medical Center, CHA University School of Medicine, Gumi, Korea.
Ho-Jae LeeDepartment of Orthopedic Surgery, CHA Gumi Medical Center, CHA University School of Medicine, Gumi, Korea.
Tae-Ho KimDepartment of Orthopedic Surgery, CHA Gumi Medical Center, CHA University School of Medicine, Gumi, Korea.
Young-Gun KimDepartment of Orthopedic Surgery, CHA Gumi Medical Center, CHA University School of Medicine, Gumi, Korea.
Gumi University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTreatment of unstable clavicle fractures remains a challenge for orthopedic surgeons, but the evolution of treatment strategies has allowed for reliable results with minimal complications. Although several surgical options exist, open reduction with plating remains the treatment of choice for clavicle fractures. The purpose of this study is to determine an easy way to achieve successful preplating reduction while minimizing surrounding soft tissue damage during treatment of midshaft fractures of the clavicle.

methodsA retrospective study included all consecutive adult patients operated on by a single surgeon for acute displaced clavicular midshaft fracture between January 2010 and October 2014. Hybrid technique with interfragmentary cerclage wiring, temporary axial K-wire pinning, or their combination was used in all patients. The demographic data and clinical outcomes, including operation time, union time, restoration of anatomy, shoulder functional score, and complications were evaluated.

resultsThere were 54 male and 19 female patients, with an average age of 39.3 years (range, 18 to 77 years) for males and 58.3 years (range, 39 to 77 years) for females. They were followed up for 24 months (range, 12 to 44 months). All patients had reliable bone union after surgery using interfragmentary cerclage wiring and temporary axial K-wire fixation; fracture union was obtained at an average of 11.7 weeks (range, 8 to 21 weeks) postoperatively. Additionally, there was no postoperative loss of fracture reduction or plate loosening. At the final follow-up, all patients had regained excellent functional outcomes.

conclusionsThe cognizant effort to achieve anatomic reduction without surrounding soft tissue insult before definitive plating allows excellent radiologic and functional outcomes. Interfragmentary cerclage wiring and temporary axial K-wire pinning can overcome difficulties associated with unstable clavicle fractures to allow proper fracture reduction. In this article, we introduce a concise technique for achieving the desired outcomes reliably and efficiently when treating unstable clavicle midshaft fractures.

Indexed as

Bone WiresAdolescentAdultAgedClavicleFemaleFracture Fixation, InternalFractures, BoneHumansMaleMiddle AgedPostoperative ComplicationsRetrospective StudiesYoung AdultClavicleInterfragmentary cerclage wiringMidshaft fractureTemporary axial K-wire pinning

Identifiers

PMID29854336
PMCPMC5964261
OpenAlexW2804576941

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked