ArticleMagnetic resonance in medicine2019
Assessment of frequency drift on CEST MRI and dynamic correction: application to gagCEST at 7 T.
Article in Magnetic resonance in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed.
- Dynamic glucose-enhanced MRI in brain tumors.Magma (New York, N.Y.) · 2026Review
- Chemical exchange saturation transfer NMR: An analytical tool and its applications.Magnetic resonance letters · 2026Review
- A Novel CEST-Based Approach for Reliably Assessing Skeletal Muscle Oxidative Phosphorylation: OXCEST.Magnetic resonance in medicine · 2026Article
- Rapid and simplified post-processing for simultaneousMagnetic resonance in medicine · 2025Article
- Chemical Exchange Saturation Transfer Imaging in Neuroinflammation: Methods, Challenges, and Recommendations.International journal of molecular sciences · 2025Review
- Human liver CEST imaging at 7 T: Impact ofMagnetic resonance in medicine · 2025Article
- RF Heating Effects in CEST NMR with HyperpolarizedChemphyschem : a European journal of chemical physics and physical chemistry · 2025Article
- Rosette Spectroscopic Imaging for Whole-Brain Slab Metabolite Mapping at 7T: Acceleration Potential and Reproducibility.Human brain mapping · 2025Article
- Gaining Insight into Updated MR Imaging for Quantitative Assessment of Cartilage Injury in Knee Osteoarthritis.Current rheumatology reports · 2024Review
- Improved postprocessing of dynamic glucose-enhanced CEST MRI for imaging brain metastases at 3 T.European radiology experimental · 2023Article
- BTomography (Ann Arbor, Mich.) · 2022Article
- Review and consensus recommendations on clinical APT-weighted imaging approaches at 3T: Application to brain tumors.Magnetic resonance in medicine · 2022Review
- Towards robust glucose chemical exchange saturation transfer imaging in humans at 3 T: Arterial input function measurements and the effects of infusion time.NMR in biomedicine · 2022Article
- GLINT: GlucoCEST in neoplastic tumors at 3 T-clinical results of GlucoCEST in gliomas.Magma (New York, N.Y.) · 2022Article
- What do we know about dynamic glucose-enhanced (DGE) MRI and how close is it to the clinics? Horizon 2020 GLINT consortium report.Magma (New York, N.Y.) · 2022Review
- Whole-brain amide CEST imaging at 3T with a steady-state radial MRI acquisition.Magnetic resonance in medicine · 2021Article
- Clinical translation of amide proton transfer (APT) MRI for ischemic stroke: a systematic review (2003-2020).Quantitative imaging in medicine and surgery · 2021Review
- Delayed urea differential enhancement CEST (dudeCEST)-MRI with TMagnetic resonance in medicine · 2021Article
- Real-time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T.Magnetic resonance in medicine · 2021Article
- High-sensitivity CEST mapping using a spatiotemporal correlation-enhanced method.Magnetic resonance in medicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeTo investigate the effect of a frequency drift of the static magnetic field on 3D CEST MRI based on glycosaminoglycans (GAGs) of articular cartilage at 7 T and to introduce a retrospective correction method that uses the phase images of the gradient-echo readout.
methodsRepeated gagCEST and B
resultsThe frequency drift of the MRI scanner strongly influences the gagCEST signal in the articular cartilage of the human knee joint. The gagCEST signal in the articular cartilage is changed by 0.18%/Hz while an average drift of 0.7 ± 0.2 Hz/minute was observed. The proposed correction method can be applied retrospectively without the need of additional measurements and provides improved comparability and reproducibility for gagCEST studies. This correction method may also be of interest for other applications of CEST MRI.
conclusionProspective or retrospective correction of the frequency drift of the MRI scanner is essential for reproducible gagCEST measurements. The proposed retrospective correction method fulfills this requirement without the need of additional measurements.