Evidence map›Paper›PMID 29846804›Full record

Trial reportEuropean radiology2018

Can digital breast tomosynthesis perform better than standard digital mammography work-up in breast cancer assessment clinic?

S Mall, J Noakes, M Kossoff, W Lee, M McKessar, A Goy, J Duncombe, M Roberts, B Giuffre, A Miller and 15 more

Abstract readMulticenter StudyRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in European radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 3 pooled it
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 3 syntheses or guidelines pooled it, 28 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Article
  5. Review
  6. Article
  7. Article
  8. Breast biopsy techniques in a global setting-clinical practice review.Translational breast cancer research : a journal focusing on translational research in breast cancer · 2023
    Review
  9. Article
  10. Article
  11. Review
  12. Review
  13. Digital Breast Tomosynthesis: Update on Technology, Evidence, and Clinical Practice.Radiographics : a review publication of the Radiological Society of North America, Inc
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

25 authors at 2 institutions in 1 country.

S MallFaculty of Health Sciences, University of Sydney, 75 East Street, Room M204, Lidcombe, New South Wales, Australia. smal5514@uni.sydney.edu.au.ORCID http://orcid.org/0000-0001-6763-7514
J NoakesNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
M KossoffNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
W LeeNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
M McKessarNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
A GoyNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
J DuncombeNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
M RobertsNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
B GiuffreNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
A MillerNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
N BholaNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
C KapoorNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
C ShearmanNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
G DaCostaNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
S ChoiNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
J SterbaNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
M KayNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
K BruderlinNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
N WinartaNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
K DonohueNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
B Macdonell-ScottNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
F KlijnsmaNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
K SuzukiNorthern Sydney & Central Coast BreastScreen, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
P BrennanFaculty of Health Sciences, University of Sydney, 75 East Street, Room M204, Lidcombe, New South Wales, Australia.
C Mello-ThomsFaculty of Health Sciences, University of Sydney, 75 East Street, Room M204, Lidcombe, New South Wales, Australia.
Royal North Shore Hospital · AUThe University of Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the efficacy of use of digital breast tomosynthesis (DBT) with standard digital mammography (DM) workup views in the breast cancer assessment clinic. MATERIALS AND

methodsThe Tomosynthesis Assessment Clinic trial (TACT), conducted between 16 October 2014 and 19 April 2016, is an ethics-approved, monocenter, multireader, multicase split-plot reading study. After written informed consent was obtained, 144 females (age > 40 years) who were recalled to the assessment clinic were recruited into TACT. These cases (48 cancers) were randomly allocated for blinded review of (1) DM workup and (2) DBT, both in conjunction with previous DM from the screening examination. Fifteen radiologists of varying experience levels in the Australia BreastScreen Program were included in this study, wherein each radiologist read 48 cases (16 cancers) in 3 non-overlapping blocks. Diagnostic accuracy was measured by means of sensitivity, specificity, and positive (PPV) and negative predictive values (NPV). The receiver-operating characteristic area under the curve (AUC) was calculated to determine radiologists' performances.

resultsUse of DBT (AUC = 0.927) led to improved performance of the radiologists (z = 2.62, p = 0.008) compared with mammography workup (AUC = 0.872). Similarly, the sensitivity, specificity, PPV, and NPV of DBT (0.93, 0.75, 0.64, 0.96) were higher than those of the workup (0.90, 0.56, 0.49, 0.92). Most radiologists (80%) performed better with DBT than standard workup. Cancerous lesions on DBT appeared more severe (U = 33,172, p = 0.02) and conspicuous (U = 24,207, p = 0.02). There was a significant reduction in the need for additional views (χ

conclusionsDBT has the potential to increase diagnostic accuracy and simplify the assessment process in the breast cancer assessment clinic. KEY POINTS: • Use of DBT in the assessment clinic results in increased diagnostic accuracy. • Use of DBT in the assessment clinic improves performance of radiologists and also increases the confidence in their decisions. • DBT may reduce the need for additional views, ultrasound imaging, and biopsy.

Indexed as

AustraliaBreast NeoplasmsFemaleHumansIncidenceMammographyMass ScreeningRadiographic Image EnhancementROC Curve2D mammography3D mammographyBreast cancerDigital breast tomosynthesisDigital mammography

Identifiers

PMID29846804
OpenAlexW2806707478

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.