ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2019
Increased valgus laxity in flexion with greater tibial resection depth following total knee arthroplasty.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 9 citations in OpenAlex.
- Limited Accuracy of Tibial Stylus Measurements in Conventional Total Knee Arthroplasty.Journal of clinical medicine · 2026Article
- Article
- Importance of the gender and preoperative knee sagittal alignment to avoid unnecessary tibial resection in TKR.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2021Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSoft tissue balancing is of central importance to outcome following total knee arthroplasty (TKA). However, there are lack of data analysing the effect of tibial bone cut thickness on valgus laxity. A cadaveric study was undertaken to assess the biomechanical consequences of tibial resection depth on through range knee joint valgus stability. We aimed to establish a maximum tibial resection depth, beyond which medial collateral ligament balancing becomes challenging, and a constrained implant should be considered.
methodsEleven cadaveric specimens were included for analysis. The biomechanical effects of increasing tibial resection were studied, with bone cuts made at 6, 10, 14, 18 and 24 mm from the lateral tibial articular surface. A computer navigation system was used to perform the tibial resection and to measure the valgus laxity resulting from a torque of 10 Nm. Measurements were taken in four knee positions: 0° or extension, 30°, 60° and 90° of flexion. Intra-observer reliability was assessed. A minimum sample size of eight cadavers was necessary. Statistical analysis was performed using a nonparametric Spearman's ranking correlation matrix at the different stages: in extension, at 30°, 60° and 90° of knee flexion. Significance was set at p < 0.05.
resultsThere was no macroscopic injury to the dMCL or sMCL in any of the specimens during tibial resection. There was no significant correlation found between the degree of valgus laxity and the thickness of the tibial cut with the knee in extension. There was a statistically significant correlation between valgus laxity and the thickness of the tibial cut in all other knee flexion positions: 30° (p < 0.0001), 60° (p < 0.001) and 90° (p < 0.0001). We identified greater than 5° of valgus laxity, at 90° of knee flexion, after a tibial resection of 14 mm.
conclusionIncreased tibial resection depth is associated with significantly greater valgus laxity when tested in positions from 30° to 90° of flexion, despite stability in extension. Greater than 5° of laxity was identified with a tibial resection of 14 mm. When a tibial bone cut of 14 mm or greater is necessary, as may occur with severe preoperative coronal plane deformity, it is recommended to consider the use of a constrained knee prosthesis.