Evidence map›Paper›PMID 29844329›Full record

ArticleScientific reports2018

Fabrication and In Vitro Characterization of a Tissue Engineered PCL-PLLA Heart Valve.

Anwarul Hasan, Sherif Soliman, Fatima El Hajj, Yuan-Tsan Tseng, Huseyin C Yalcin, Hany Elsayed Marei

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
3.7field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 80 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 3 countries.

Anwarul HasanDepartment of Mechanical and Industrial Engineering, College of Engineering, Qatar University, Doha, Qatar. ahasan@qu.edu.qa.ORCID 0000-0001-8380-2233
Sherif SolimanBiostage, Inc., Holliston, MA, 01746, USA.
Fatima El HajjBiomedical Engineering, Faculty of Engineering and Architecture, American University of Beirut, Beirut, 11-0236, Lebanon.
Yuan-Tsan TsengDivision of Qatar Cardiovascular Research Center, Sidra Medicine, Doha, Qatar.ORCID 0000-0002-3511-7191
Huseyin C YalcinBiomedical Research Center, Qatar University, Doha, PO Box 2713, Qatar.
Hany Elsayed MareiBiomedical Research Center, Qatar University, Doha, PO Box 2713, Qatar.
Qatar University · QAAmerican University of Beirut · LBHarefield Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heart valve diseases are among the leading causes of cardiac failure around the globe. Nearly 90,000 heart valve replacements occur in the USA annually. Currently, available options for heart valve replacement include bioprosthetic and mechanical valves, both of which have severe limitations. Bioprosthetic valves can last for only 10-20 years while patients with mechanical valves always require blood-thinning medications throughout the remainder of the patient's life. Tissue engineering has emerged as a promising solution for the development of a viable, biocompatible and durable heart valve; however, a human implantable tissue engineered heart valve is yet to be achieved. In this study, a tri-leaflet heart valve structure is developed using electrospun polycaprolactone (PCL) and poly L-lactic acid (PLLA) scaffolds, and a set of in vitro testing protocol has been developed for routine manufacturing of tissue engineered heart valves. Stress-strain curves were obtained for mechanical characterization of different valves. The performances of the developed valves were hemodynamically tested using a pulse duplicator, and an echocardiography machine. Results confirmed the superiority of the PCL-PLLA heart valve compared to pure PCL or pure PLLA. The developed in vitro test protocol involving pulse duplicator and echocardiography tests have enormous potential for routine application in tissue engineering of heart valves.

Indexed as

BioprosthesisHeart Valve ProsthesisAnimalsCells, CulturedCell SurvivalEquipment DesignFemaleHeart ValvesHumansMice, Inbred C57BLPolyestersStem CellsSwineTissue EngineeringTissue ScaffoldspolycaprolactonePolyesterspoly(lactide)

Identifiers

PMID29844329
PMCPMC5974353
OpenAlexW2806673964

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.