ArticleJournal of materials science. Materials in medicine2018
Properties of collagen-based hemostatic patch compared to oxidized cellulose-based patch.
Article in Journal of materials science. Materials in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 19 citations in OpenAlex.
- Association Between Collagen-Based Hemostatic Patch Use and Patient-Reported Recovery After Bilateral Thyroidectomy: A Retrospective Cohort Study.Journal of clinical medicine · 2026Article
- Assessment of collagen hemostatic membrane and sponge in alveolar sockets: A quasi-experimental prospective clinical study.Medicina oral, patologia oral y cirugia bucal · 2026Article
- Robust water-activated tissue adhesive patch for arterial/heart wound closure after intervention surgery.Nature communications · 2026Article
- Biomaterials in pancreatic surgery: progress and challenges in preoperative, intraoperative and postoperative care.Theranostics · 2026Review
- Development and Evaluation of Thrombin-Loaded Gelatin Hemostatic Sheets for Spinal Surgery Applications.Spine surgery and related research · 2025Article
- Evaluation of Different Commercial Sealing Hemostatic Patches for Their Selection as Reservoirs for Localized Intraperitoneal Chemotherapy.ACS pharmacology & translational science · 2025Article
- Evaluation of toxicity, local biocompatibility, biodegradation, and systemic metabolism of cellulose/alginate/strontium apatite membranes implanted subcutaneously in mice.Acta cirurgica brasileira · 2025Article
- Efficacy of a novel polyoxazoline-based hemostatic patch in liver and spleen surgery.World journal of emergency surgery : WJES · 2023Article
- Article
- Effect of naturally derived surgical hemostatic materials on the proliferation of A549 human lung adenocarcinoma cells.Materials today. Bio · 2022Article
- Versatility and clinical effectiveness of a synthetic sealing hemostatic patch as alternative to parenchyma suturing in laparoscopic partial nephrectomy.Surgical endoscopy · 2022Article
- Application and outlook of topical hemostatic materials: a narrative review.Annals of translational medicine · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Two self-adhering hemostatic patches, based on either PEG-coated collagen (PCC) or PEG-coated oxidized cellulose (PCOC), are compared regarding to maximum burst pressure, mechanical stability, and swelling. In addition, the induction of tissue adhesions by the materials was assessed in a rabbit liver abrasion model. Both materials showed comparable sealing efficacy in a burst pressure test (37 ± 16 vs. 35 ± 8 mmHg, P = 0.730). After incubation in human plasma, PCC retained its mechanical properties over the test period of 8 h, while PCOC showed faster degradation after the 2 h time-point. The degradation led to a significantly decreased force at break (minimum force at break 0.55 N during 8 h for PCC, 0.27 N for PCOC; p < 0.001). Further, PCC allowed significantly higher deformation before break (52% after 4 h and 50% after 8 h for PCC, 18% after 4 h and 23% after 8 h for PCOC; p = 0.003 and p < 0.001 for 4 h and 8 h, respectively) and showed less swelling in human plasma (maximum increase in thickness: ~20% PCC, ~100% PCOC). Faster degradation of PCOC was visible macroscopically and histologically in vivo after 14 days. PCC showed visible structural residues with little cellular infiltration while strong infiltration with no remaining structural material was seen with PCOC. In vivo, a higher incidence of adhesion formation after PCOC application was detected. In conclusion, PCC has more reliable mechanical properties, reduced swelling, and less adhesion formation than PCOC. PCC may offer greater clinical benefit for surgeons in procedures that have potential risk for body fluid leakage or that require prolonged mechanical stability.