Evidence map›Paper›PMID 29796735›Full record

ArticleJournal of the American Society for Mass Spectrometry2019

Development and Evaluation of a Reverse-Entry Ion Source Orbitrap Mass Spectrometer.

Michael L Poltash, Jacob W McCabe, John W Patrick, Arthur Laganowsky, David H Russell

Erratum issuedAbstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Modified Ion Source for the Improved Collisional Activation of Protein Complexes.Journal of the American Society for Mass Spectrometry · 2023
    Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Implementing Digital-Waveform Technology for ExtendedJournal of the American Society for Mass Spectrometry · 2021
    Article
  11. Article
  12. Review
  13. Development of Native MS Capabilities on an Extended Mass Range Q-TOF MS.International journal of mass spectrometry · 2020
    Article
  14. Article
  15. Article
  16. Native IM-Orbitrap MS: Resolving What Was Hidden.Trends in analytical chemistry : TRAC · 2020
    Article
  17. Review
  18. Fundamental Studies of New Ionization Technologies and Insights from IMS-MS.Journal of the American Society for Mass Spectrometry · 2019
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Michael L PoltashDepartment of Chemistry, Texas A&M University, College Station, TX, 77843, USA.
Jacob W McCabeDepartment of Chemistry, Texas A&M University, College Station, TX, 77843, USA.
John W PatrickDepartment of Chemistry, Texas A&M University, College Station, TX, 77843, USA.
Arthur LaganowskyDepartment of Chemistry, Texas A&M University, College Station, TX, 77843, USA. alaganowsky@chem.tamu.edu.
David H RussellDepartment of Chemistry, Texas A&M University, College Station, TX, 77843, USA. russell@chem.tamu.edu.

Funding

Native ion mobility mass spectrometry studies of potassium inward rectifier channels: insight into gating and lipid bindingDP2GM123486 · NIGMS · TEXAS A&M UNIVERSITY HEALTH SCIENCE CTR · PI LAGANOWSKY, ARTHUR D · 2016 to 2016
$2.2M
Development of high resolution mobility measurements for structural biologyR01GM121751 · NIGMS · TRUSTEES OF INDIANA UNIVERSITY · PI CLEMMER, DAVID E., LAGANOWSKY, ARTHUR D · 2017 to 2020
$1.7M
National Institutes of Health DP2GM123486National Institutes of Health GM121751-01A1National Science Foundation CHE-1707675NIGMS NIH HHS DP2 GM123486NIGMS NIH HHS R01 GM121751
6 · The paper itself

Abstract

As a step towards development of a high-resolution ion mobility mass spectrometer using the orbitrap mass analyzer platform, we describe herein a novel reverse-entry ion source (REIS) coupled to the higher-energy C-trap dissociation (HCD) cell of an orbitrap mass spectrometer with extended mass range. Development of the REIS is a first step in the development of a drift tube ion mobility-orbitrap MS. The REIS approach retains the functionality of the commercial instrument ion source which permits the uninterrupted use of the instrument during development as well as performance comparisons between the two ion sources. Ubiquitin (8.5 kDa) and lipid binding to the ammonia transport channel (AmtB, 126 kDa) protein complex were used as model soluble and membrane proteins, respectively, to evaluate the performance of the REIS instrument. Mass resolution obtained with the REIS is comparable to that obtained using the commercial ion source. The charge state distributions for ubiquitin and AmtB obtained on the REIS are in agreement with previous studies which suggests that the REIS-orbitrap EMR retains native structure in the gas phase. Graphical Abstract ᅟ.

Indexed as

ExactiveInstrument developmentIon sourceMembrane proteinOrbitrap

Identifiers

PMID29796735
PMCPMC6251776

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.