Evidence map›Paper›PMID 29796294›Full record

ArticlePilot and feasibility studies2018

Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study.

Suman Rao, Prashanth Thankachan, Bharadwaj Amrutur, Maryann Washington, Prem K Mony

Open access · goldAbstract read
In one paragraph

Article in Pilot and feasibility studies, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Wearables - A Revolution in Neonatal Monitoring?Indian journal of pediatrics · 2023
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Suman Rao1Department of Neonatology, St John's Medical College Hospital, St John's National Academy of Health Sciences, Bangalore, 560034 India.
Prashanth Thankachan2Division of Epidemiology and Population Health, St John's Research Institute, St John's National Academy of Health Sciences, Bangalore, 560034 India.
Bharadwaj Amrutur3Robert Bosch Center for Cyber Physical Systems, Indian Institute of Science, Bangalore, 560012 India.
Maryann Washington2Division of Epidemiology and Population Health, St John's Research Institute, St John's National Academy of Health Sciences, Bangalore, 560034 India.
Prem K Mony2Division of Epidemiology and Population Health, St John's Research Institute, St John's National Academy of Health Sciences, Bangalore, 560034 India.ORCID 0000-0002-1399-0520
St. John's National Academy of Health Sciences · INRobert Bosch (China) · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRemote biomonitoring of vital parameters in hospitals and homes has the potential to improve coverage and quality of maternal and neonatal health. Wearable sensors coupled with modern information and communication technology now offer an opportunity to monitor temperatures and kangaroo mother care (KMC) adherence in a continuous and real-time manner remotely for several days' duration in hospital and home settings. Using an innovative remote biomonitoring device to measure both temperature and baby position, we undertook a techno-feasibility study in preparation for a clinical trial.

methodsWe designed and developed a wearable sensor for tracking KMC adherence and neonatal temperature, using social innovation design principles. After screening mother-infant dyads using clinical and logistic eligibility criteria, we piloted this wearable sensor along with a gateway device and the commercial cellular network. The dyads were recruited during hospitalization and followed up in the hospital and home phases for several days. Simple descriptive statistical analysis was undertaken.

resultsRecruitment rate was 50% (6/12), and consenting rate was 83% (5/6) during a 2-month period. These five neonates contributed a total of 39 study days (15 hospital days and 24 home days). Their mean [± standard deviation (S.D.)] birth weight was 1490 (± 244) g.The mean (± S.D.) of the vital signs for the five babies was temperature [36.5 °C (± 0.3)], heart rate [146.5/min (± 14)], and oxygen saturation [94% (± 4)]. No severe or moderate side-effects were noted; one baby developed mild dermatitis under the device that was transient and self-limiting, yielding an incidence proportion of 20% and incidence rate of 2.6/100 person-days.None of the mothers reported any discomfort with the use of the device. Temperatures detected from 81 paired readings revealed that those from the wearable sensor were 0.2 °C lower than those detected by clinical thermometers [36.4 (± 0.7)

conclusionsThe pilot study has shown that it is feasible and acceptable to track KMC adherence as well as maternal and newborn temperatures in a potentially safe manner on a real-time mode for several days' duration during hospitalization and home phases. The pilot has also helped inform modifications in clinical monitoring, technological modifications, and logistics planning in preparation for the definitive clinical trial.

trial registrationClinical Trials Registry of India, CTRI/2017/09/009789.

Indexed as

Kangaroo mother caremHealthMonitoringNeonatal healthSignsTemperatureVitalWearable sensor

Identifiers

PMID29796294
PMCPMC5961490
OpenAlexW2807377893

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.