Evidence map›Paper›PMID 29791518›Full record

ArticlePloS one2018

Multi-Operational Selective Computer-Assisted Targeting of hepatocellular carcinoma-Evaluation of a novel approach for navigated tumor ablation.

Pascale Tinguely, Marius Schwalbe, Torsten Fuss, Dominik P Guensch, Andreas Kohler, Iris Baumgartner, Stefan Weber, Daniel Candinas

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Pascale TinguelyDepartment of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.ORCID 0000-0001-6836-8045
Marius SchwalbeARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Torsten FussDepartment of Clinical and Interventional Angiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Dominik P GuenschDepartment of Anesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Andreas KohlerDepartment of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Iris BaumgartnerDepartment of Clinical and Interventional Angiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Stefan WeberARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Daniel CandinasDepartment of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
University of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo facilitate precise local ablation of hepatocellular carcinoma (HCC) in a setting of combined ablation and transarterial chemoembolization (TACE), we evaluated accuracy and efficiency of a novel technique for navigated positioning of ablation probes using intrahepatic tumor referencing and electromagnetic (EM) guidance, in a porcine model.

methodsAn angiographic wire with integrated EM reference sensor at its tip was inserted via a transarterial femoral access and positioned in the vicinity of artificial liver tumors. The resulting offset distance between the tumor center and the intrahepatic endovascular EM reference was calculated. Subsequently, EM tracked ablation probes were inserted percutaneously and navigated toward the tumor center, relying on continuous EM guidance via the intrahepatic reference. Targeting accuracy was assessed as the Euclidean distance between the tip of the ablation probe and the tumor center (Target Positioning Error, TPE). Procedural efficiency was assessed as time efforts for tumor referencing and tumor targeting.

resultsIn 6 animals, 124 targeting measurements were performed with an offset distance < 30 mm (clinically most feasible position), resulting in a mean TPE of 2.9 ± 1.6 mm. No significant correlation between the TPE and different intrahepatic offset distances (range 21 to 61 mm, n = 365) was shown as long as the EM reference was placed within the liver. However, the mean TPE increased when placing the EM reference externally on the animal skin (p < 0.01). TPE was similar when targeting under continuous ventilation or in apnea (p = 0.50). Mean time for tumor referencing and navigated targeting was 6.5 ± 3.8 minutes and 14 ± 8 seconds, respectively.

conclusionThe proposed technique allows precise and efficient navigated positioning of ablation probes into liver tumors in the animal model. We introduce a simple approach suitable for combined ablation and TACE of HCC in a single treatment session.

Indexed as

Ablation TechniquesAnimalsCarcinoma, HepatocellularElectromagnetic FieldsLiver NeoplasmsSurgery, Computer-AssistedSwineTreatment Outcome

Identifiers

PMID29791518
PMCPMC5965844
OpenAlexW2803176031

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.