Evidence map›Paper›PMID 29777354›Full record

Trial reportSurgical endoscopy2018

Randomized study of the influence of two-dimensional versus three-dimensional imaging using a novel 3D head-mounted display (HMS-3000MT) on performance of laparoscopic inguinal hernia repair.

M Patrzyk, M Klee, T Stefaniak, C D Heidecke, K Beyer

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Surgical endoscopy, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

M PatrzykDepartment of Surgery, Clinic of General Surgery, Visceral, Thoracic and Vascular Surgery, Ernst-Moritz-Arndt-University Hospital, Greifswald, Germany. patrzyk@uni-greifswald.de.
M KleeDepartment of Surgery, Clinic of General Surgery, Visceral, Thoracic and Vascular Surgery, Ernst-Moritz-Arndt-University Hospital, Greifswald, Germany.
T StefaniakDepartment of General, Endocrine and Transplant Surgery, Medical University of Gdansk, Gdańsk, Poland.
C D HeideckeDepartment of Surgery, Clinic of General Surgery, Visceral, Thoracic and Vascular Surgery, Ernst-Moritz-Arndt-University Hospital, Greifswald, Germany.
K BeyerCharité - Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12203, Berlin, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background3D laparoscopy has proven to be superior to the 2D approach in experimental settings. The aim of the present study was to investigate the influence of 3D laparoscopy using a novel head-mounted display on the performance of defined steps within a laparoscopic inguinal hernia repair. This effect was investigated both in laparoscopically advanced surgeons and in beginners.

methodsPatients suffering from symptomatic inguinal hernia were randomly assigned to laparoscopic hernia repair using either a head-mounted 3D display or a conventional 2D laparoscopic approach. Operative performance of both groups was compared in terms of the time taken for mesh placement and for peritoneal suturing. Additionally, quality of imaging and physical discomfort were assessed.

resultsThe use of a head-mounted 3D display was able to shorten the time required for placement of the mesh as well as that for peritoneal suturing, both for experienced and novice surgeons when compared to the conventional 2D approach. 3D laparoscopy was significantly superior to 2D laparoscopy in terms of depth perception, image sharpness and image contrast. Additionally, increased impairment caused by ghosting effects could not be detected in 3D laparoscopy. Evaluation of image quality was independent of experience in laparoscopic surgery. However, use of a head-mounted 3D display resulted in a significant impairment of surgeon's comfort when compared to 2D laparoscopy. Thereby, the greatest impairment was caused by ear discomfort.

conclusionsThis is the first study examining the effect of a head-mounted 3D system on the performance of laparoscopy in a randomized controlled trial (RCT) showing a clear advantage of this system in surgical performance as well as in depth perception and image quality.

Indexed as

Hernia, InguinalHerniorrhaphyImaging, Three-DimensionalLaparoscopyDepth PerceptionFemaleHumansImage EnhancementMaleMiddle AgedOutcome and Process Assessment, Health CareUltrasonography, Interventional2D3DInguinal hernia repairLaparoscopic

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked