Evidence map›Paper›PMID 29774594›Full record

ArticleMagnetic resonance in medicine2018

In vivo characterization of 3D skull and brain motion during dynamic head vibration using magnetic resonance elastography.

Ziying Yin, Yi Sui, Joshua D Trzasko, Phillip J Rossman, Armando Manduca, Richard L Ehman, John Huston

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ziying YinDepartment of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota.ORCID 0000-0003-3235-966X
Yi SuiDepartment of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota.ORCID 0000-0002-8177-1661
Joshua D TrzaskoDepartment of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota.
Phillip J RossmanDepartment of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota.
Armando ManducaDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota.
Richard L EhmanDepartment of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota.
John HustonDepartment of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota.

Funding

High Performance, Highly Deployable Head-Only MRI ScannerR01EB010065 · NIBIB · GENERAL ELECTRIC GLOBAL RESEARCH CTR · PI BERNSTEIN, MATTHEW A., FOO, THOMAS K · 2010 to 2015
$5.5M
Magnetic Resonance ElastographyR37EB001981 · NIBIB · MAYO CLINIC ROCHESTER · PI EHMAN, RICHARD L. · 2016 to 2025
$4.0M
Magnetic Resonance ElastographyR01EB001981 · NIBIB · MAYO CLINIC ROCHESTER · PI EHMAN, RICHARD L. · 2003 to 2013
$3.1M
NIBIB NIH HHS R01 EB001981NIBIB NIH HHS R01 EB010065NIBIB NIH HHS R37 EB001981NIH HHS RO1 EB001981NIH HHS RO1 EB010065Office of Naval Research Contract N00173-15-P-0618
6 · The paper itself

Abstract

purposeTo introduce newly developed MR elastography (MRE)-based dual-saturation imaging and dual-sensitivity motion encoding schemes to directly measure in vivo skull-brain motion, and to study the skull-brain coupling in volunteers with these approaches.

methodsSix volunteers were scanned with a high-performance compact 3T-MRI scanner. The skull-brain MRE images were obtained with a dual-saturation imaging where the skull and brain motion were acquired with fat- and water-suppression scans, respectively. A dual-sensitivity motion encoding scheme was applied to estimate the heavily wrapped phase in skull by the simultaneous acquisition of both low- and high-sensitivity phase during a single MRE exam. The low-sensitivity phase was used to guide unwrapping of the high-sensitivity phase. The amplitude and temporal phase delay of the rigid-body motion between the skull and brain was measured, and the skull-brain interface was visualized by slip interface imaging (SII).

resultsBoth skull and brain motion can be successfully acquired and unwrapped. The skull-brain motion analysis demonstrated the motion transmission from the skull to the brain is attenuated in amplitude and delayed. However, this attenuation (%) and delay (rad) were considerably greater with rotation (59 ± 7%, 0.68 ± 0.14 rad) than with translation (92 ± 5%, 0.04 ± 0.02 rad). With SII the skull-brain slip interface was not completely evident, and the slip pattern was spatially heterogeneous.

conclusionThis study provides a framework for acquiring in vivo voxel-based skull and brain displacement using MRE that can be used to characterize the skull-brain coupling system for understanding of mechanical brain protection mechanisms, which has potential to facilitate risk management for future injury.

Indexed as

Elasticity Imaging TechniquesMagnetic Resonance ImagingAdultAlgorithmsBrainBrain Injuries, TraumaticFemaleHealthy VolunteersHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMaleMotionPhantoms, ImagingSkullVibrationmagnetic resonance elastographymechanical characterizationmotionskull and brain couplingskull and brain interfacetissue

Identifiers

PMID29774594
PMCPMC6240411

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.