ArticleSensors (Basel, Switzerland)2018

Three-Dimensional Terahertz Coded-Aperture Imaging Based on Geometric Measures.

Shuo Chen, Xiaoqiang Hua, Hongqiang Wang, Chenggao Luo, Yongqiang Cheng, Bin Deng

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shuo ChenSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. chenshuo13@nudt.edu.cn.
Xiaoqiang HuaSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. huaxiaoqiang12@nudt.edu.cn.
Hongqiang WangSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. wanghongqiang@nudt.edu.cn.
Chenggao LuoSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. luochenggao@nudt.edu.cn.
Yongqiang ChengSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. yqcheng@nudt.edu.cn.
Bin DengSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. dengbin@nudt.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

For synthetic aperture radars, it is difficult to achieve forward-looking and staring imaging with high resolution. Fortunately, terahertz coded-aperture imaging (TCAI), an advanced radar imaging technology, can solve this problem by producing various irradiation patterns with coded apertures. However, three-dimensional (3D) TCAI has two problems, including a heavy computational burden caused by a large-scale reference signal matrix, and poor resolving ability at low signal-to-noise ratios (SNRs). This paper proposes a 3D imaging method based on geometric measures (GMs), which can reduce the computational burden and achieve high-resolution imaging for low SNR targets. At extremely low SNRs, it is difficult to detect the range cells containing scattering information with an ordinary range profile. However, this difficulty can be overcome through GMs, which can enhance the useful signal and restrain the noise. By extracting useful data from the range profile, target information in different imaging cells can be simultaneously reconstructed. Thus, the computational complexity is distinctly reduced when the 3D image is obtained by combining reconstructed 2D imaging results. Based on the conventional TCAI (C-TCAI) model, we deduce and build a GM-based TCAI (GM-TCAI) model. Compared with C-TCAI, the experimental results demonstrate that GM-TCAI achieves a more impressive performance with regards to imaging ability and efficiency. Furthermore, GM-TCAI can be widely applied in close-range imaging fields, for instance, medical diagnosis, nondestructive detection, security screening, etc.

Indexed as

coded-aperture imaginggeometric measures (GMs)pulse compressionthree-dimensional (3D)

Identifiers

PMID29772676
PMCPMC5982586

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.