ArticleMedical physics2018
3D-specific absorption rate estimation from high-intensity focused ultrasound sonications using the Green's function heat kernel.
Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Model Predictive Filtering MR Temperature Imaging for Laser-Induced Interstitial Thermotherapy.Magnetic resonance in medicine · 2026Article
- Using the Tissue Impulse Response Function to Streamline Fractionated MRgFUS-Induced Hyperthermia.Cancers · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
purposeTo evaluate a numerical inverse Green's function method for deriving specific absorption rates (SARs) from high-intensity focused ultrasound (HIFU) sonications using tissue parameters (thermal conductivity, specific heat capacity, and mass density) and three-dimensional (3D) magnetic resonance imaging (MRI) temperature measurements.
methodsSAR estimates were evaluated using simulations and MR temperature measurements from HIFU sonications. For simulations, a "true" SAR was calculated using the hybrid angular spectrum method for ultrasound simulations. This "true" SAR was plugged into a Pennes bioheat transfer equation (PBTE) solver to provide simulated temperature maps, which were then used to calculate the SAR estimate using the presented method. Zero mean Gaussian noise, corresponding to temperature precisions between 0.1 and 2.0°C, was added to the temperature maps to simulate a variety of in vivo situations. Experimental MR temperature maps from HIFU sonications in a gelatin phantom monitored with a 3D segmented echo planar imaging MRI pulse sequence were also used. To determine the accuracy of the simulated and phantom data, we reconstructed temperature maps by plugging in the estimated SAR to the PBTE solver. In both simulations and phantom experiments, the presented method was compared to two previously published methods of determining SAR, a linear and an analytical method. The presented numerical method utilized the full 3D data simultaneously, while the two previously published methods work on a slice-by-slice basis.
resultsIn the absence of noise, SAR distribution estimates obtained from the simulated heating profiles match closely (within 10%) to the initial true SAR distribution. The resulting temperature distributions also match closely to the corresponding initial temperature distributions (<0.2°C RMSE). In the presence of temperature measurement noise, the SAR distributions have noise amplified by the inverse convolution process, while the resulting temperature distributions still match closely to the initial "true" temperature distributions. In general, temperature RMSE was observed to be approximately 20-30% higher than the level of the added noise. By contrast, the previously published linear method is less sensitive to noise, but significantly underpredicts the SAR. The analytic method is also less sensitive to noise and matches SAR in the central plane, but greatly underpredicts in the longitudinal direction. Similar observations are made from the phantom studies. The described numerical inverse Green's function method is very fast - at least two orders of magnitude faster than the compared methods.
conclusionThe presented numerical inverse Green's function method is computationally fast and generates temperature maps with high accuracy. This is true despite generally overestimating the true SAR and amplifying the input noise.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.