Evidence map›Paper›PMID 29769642›Full record

ArticleScientific reports2018

High-resolution Imaging of Myeloperoxidase Activity Sensors in Human Cerebrovascular Disease.

Youssef Z Wadghiri, Dung Minh Hoang, Anita Leporati, Matthew J Gounis, Aurora Rodríguez-Rodríguez, Mary L Mazzanti, John P Weaver, Ajay K Wakhloo, Peter Caravan, Alexei A Bogdanov

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 29 citations in OpenAlex.

  1. Review
  2. Article
  3. Imaging of Intracranial Saccular Aneurysms.Stroke (Hoboken, N.J.) · 2023
    Review
  4. Pathologically triggeredActa pharmaceutica Sinica. B · 2023
    Article
  5. Article
  6. Review
  7. Biophysical targeting of high-risk cerebral aneurysms.Bioengineering & translational medicine · 2022
    Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Imaging inflammation and its resolution in health and disease: current status, clinical needs, challenges, and opportunities.FASEB journal : official publication of the Federation of American Societies for Experimental Biology · 2019
    Review
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Youssef Z WadghiriNew York University School of Medicine, Department of Radiology, Centre for Advanced Imaging Innovation & Research (CAI2R) and Bernard & Irene Schwartz Centre for Biomedical Imaging, New York, NY, USA.
Dung Minh HoangNew York University School of Medicine, Department of Radiology, Centre for Advanced Imaging Innovation & Research (CAI2R) and Bernard & Irene Schwartz Centre for Biomedical Imaging, New York, NY, USA.
Anita LeporatiDepartment of Radiology, University of Massachusetts Medical School, Worcester, MA, USA.
Matthew J GounisDepartment of Radiology, University of Massachusetts Medical School, Worcester, MA, USA.
Aurora Rodríguez-RodríguezA. Martinos' Centre for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA.
Mary L MazzantiDepartment of Radiology, University of Massachusetts Medical School, Worcester, MA, USA.
John P WeaverDepartment of Neurosurgery, University of Massachusetts Medical School, Worcester, MA, USA.
Ajay K WakhlooDepartment of Radiology, University of Massachusetts Medical School, Worcester, MA, USA.
Peter CaravanA. Martinos' Centre for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA.ORCID 0000-0002-3179-6537
Alexei A BogdanovDepartment of Radiology, University of Massachusetts Medical School, Worcester, MA, USA. Alexei.Bogdanov@umassmed.edu.ORCID 0000-0003-4806-5869
University of Massachusetts Chan Medical School · USMassachusetts General Hospital · USNew York University · US

Funding

Vaccine FacilityP30CA016087 · NCI · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI ADRIANA HEGUY · 1985 to 2026
$83.1M
TR&D 4: Revealing Microstructure: Biophysical modeling and validation for discovery and clinical careP41EB017183 · NIBIB · NEW YORK UNIVERSITY SCHOOL OF MEDICINE · PI Hersh Chandarana · 2014 to 2026
$19.3M
MR SIGNAL AMPLIFICATION FOR RECEPTOR IMAGINGR01EB000858 · NIBIB · UNIV OF MASSACHUSETTS MED SCH WORCESTER · PI BOGDANOV, ALEXEI A. · 2003 to 2022
$6.0M
Unruptured Intracranial Aneurysms: Rupture-Risk Assessment by Non-Invasive Molecular ImagingR01NS091552 · NINDS · UNIV OF MASSACHUSETTS MED SCH WORCESTER · PI BOGDANOV, ALEXEI A., GOUNIS, MATTHEW JOHN · 2015 to 2018
$2.1M
Molecular fluorescence lifetime sensor of pro-inflammatory signaling in diabetesR01DK095728 · NIDDK · UNIV OF MASSACHUSETTS MED SCH WORCESTER · PI BOGDANOV, ALEXEI A. · 2014 to 2017
$1.5M
Molecular Imaging to Determine the Risk of Rupture of Cerebral AneurysmsR21NS061132 · NINDS · UNIV OF MASSACHUSETTS MED SCH WORCESTER · PI BOGDANOV, ALEXEI A. · 2008 to 2009
$400k
NCI NIH HHS P30 CA016087NIBIB NIH HHS P41 EB017183NIBIB NIH HHS R01 EB000858NIDDK NIH HHS R01 DK095728NINDS NIH HHS R01 NS091552NINDS NIH HHS R21 NS061132
6 · The paper itself

Abstract

Progress in clinical development of magnetic resonance imaging (MRI) substrate-sensors of enzymatic activity has been slow partly due to the lack of human efficacy data. We report here a strategy that may serve as a shortcut from bench to bedside. We tested ultra high-resolution 7T MRI (µMRI) of human surgical histology sections in a 3-year IRB approved, HIPAA compliant study of surgically clipped brain aneurysms. µMRI was used for assessing the efficacy of MRI substrate-sensors that detect myeloperoxidase activity in inflammation. The efficacy of Gd-5HT-DOTAGA, a novel myeloperoxidase (MPO) imaging agent synthesized by using a highly stable gadolinium (III) chelate was tested both in tissue-like phantoms and in human samples. After treating histology sections with paramagnetic MPO substrate-sensors we observed relaxation time shortening and MPO activity-dependent MR signal enhancement. An increase of normalized MR signal generated by ultra-short echo time MR sequences was corroborated by MPO activity visualization by using a fluorescent MPO substrate. The results of µMRI of MPO activity associated with aneurysmal pathology and immunohistochemistry demonstrated active involvement of neutrophils and neutrophil NETs as a result of pro-inflammatory signalling in the vascular wall and in the perivascular space of brain aneurysms.

Indexed as

AdolescentAdultAgedBiosensing TechniquesCerebrovascular DisordersContrast MediaFemaleGadolinium DTPAHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMaleMiddle AgedPeroxidasePhantoms, ImagingProspective StudiesContrast MediaGadolinium DTPAMPO protein, humanPeroxidase

Identifiers

PMID29769642
PMCPMC5956082
OpenAlexW2804951747

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.