Evidence map›Paper›PMID 29764458›Full record

ReviewBMC oral health2018

Cone beam computed tomography in implant dentistry: recommendations for clinical use.

Reinhilde Jacobs, Benjamin Salmon, Marina Codari, Bassam Hassan, Michael M Bornstein

Open access · goldAbstract readReview
In one paragraph

Review in BMC oral health, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 228 papers, 11 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
228citing papers in PubMed, 11 pooled it
32.4field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

228 citing papers in PubMed, 11 syntheses or guidelines pooled it, 472 citations in OpenAlex.

  1. Pooled it
  2. Comparison of conventional two-dimensional and digital three-dimensional imaging in orthodontics : A systematic review and meta-analysis.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2026
    Pooled it
  3. Pooled it
  4. Pooled it
  5. Magnetic resonance imaging in dental implant surgery: a systematic review.International journal of implant dentistry · 2024
    Pooled it
  6. Pooled it
  7. Pooled it
  8. Pooled it
  9. Pooled it
  10. Pooled it
  11. Pooled it
  12. Trial
  13. Trial
  14. Trial
  15. Trial
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review

168 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 5 institutions in 6 countries.

Reinhilde JacobsOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, Kapucijnenvoer 33, 3000, Leuven, Belgium. reinhilde.jacobs@uzleuven.be.ORCID 0000-0002-3461-0363
Benjamin SalmonEA2496, Orofacial Pathologies, Imaging and Biotherapies Lab, Dental School Paris Descartes University, Sorbonne Paris Cité, Paris, France.
Marina CodariUnit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
Bassam HassanDepartment of Oral Function and Restorative Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Research Institute MOVE, 1081 LA, Amsterdam, The Netherlands.
Michael M BornsteinOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, Kapucijnenvoer 33, 3000, Leuven, Belgium.
Academic Center for Dentistry Amsterdam · NLIRCCS Policlinico San Donato · ITKarolinska Institutet · SEUniversité Paris Cité · FRUniversity of Hong Kong · HK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn implant dentistry, three-dimensional (3D) imaging can be realised by dental cone beam computed tomography (CBCT), offering volumetric data on jaw bones and teeth with relatively low radiation doses and costs. The latter may explain why the market has been steadily growing since the first dental CBCT system appeared two decades ago. More than 85 different CBCT devices are currently available and this exponential growth has created a gap between scientific evidence and existing CBCT machines. Indeed, research for one CBCT machine cannot be automatically applied to other systems.

methodsSupported by a narrative review, recommendations for justified and optimized CBCT imaging in oral implant dentistry are provided.

resultsThe huge range in dose and diagnostic image quality requires further optimization and justification prior to clinical use. Yet, indications in implant dentistry may go beyond diagnostics. In fact, the inherent 3D datasets may further allow surgical planning and transfer to surgery via 3D printing or navigation. Nonetheless, effective radiation doses of distinct dental CBCT machines and protocols may largely vary with equivalent doses ranging between 2 to 200 panoramic radiographs, even for similar indications. Likewise, such variation is also noticed for diagnostic image quality, which reveals a massive variability amongst CBCT technologies and exposure protocols. For anatomical model making, the so-called segmentation accuracy may reach up to 200 μm, but considering wide variations in machine performance, larger inaccuracies may apply. This also holds true for linear measures, with accuracies of 200 μm being feasible, while sometimes fivefold inaccuracy levels may be reached. Diagnostic image quality may also be dramatically hampered by patient factors, such as motion and metal artefacts. Apart from radiodiagnostic possibilities, CBCT may offer a huge therapeutic potential, related to surgical guides and further prosthetic rehabilitation. Those additional opportunities may surely clarify part of the success of using CBCT for presurgical implant planning and its transfer to surgery and prosthetic solutions.

conclusionsHence, dental CBCT could be justified for presurgical diagnosis, preoperative planning and peroperative transfer for oral implant rehabilitation, whilst striving for optimisation of CBCT based machine-dependent, patient-specific and indication-oriented variables.

Indexed as

Dental ImplantationImaging, Three-DimensionalPatient Care PlanningCone-Beam Computed TomographyCosts and Cost AnalysisHumansModels, DentalPostoperative CarePractice Guidelines as TopicPreoperative CareRadiation DosageCone beam computed tomographyDental implantsGuidelinesPresurgical planningRadiation doseVirtual patient

Identifiers

PMID29764458
PMCPMC5952365
OpenAlexW2806435360

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked