ArticlePloS one2018
Platinum corrosion products from electrode contacts of human cochlear implants induce cell death in cell culture models.
Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 1 synthesis or guideline pooled it, 50 citations in OpenAlex.
- Complications of epidural spinal stimulation: lessons from the past and alternatives for the future.Spinal cord · 2020Pooled it
- Sodium hexachloroplatinate (IV) induces concentration- and time-dependent depolarization and cytotoxicity in HEI-OC1 auditory cells.PloS one · 2026Article
- Nanomaterials and nanotechnology in otolaryngology: a narrative review.Nanomedicine (London, England) · 2025Review
- In vivo microelectrode arrays for neuroscience.Nature reviews. Methods primers · 2025Article
- Bioelectronic Neural Interfaces: Improving Neuromodulation Through Organic Conductive Coatings.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Engineered heart tissue: Design considerations and the state of the art.Biophysics reviews · 2024Review
- Article
- Article
- A Comparative Study on the Effect of Substrate Structure on Electrochemical Performance and Stability of Electrodeposited Platinum and Iridium Oxide Coatings for Neural Electrodes.Micromachines · 2023Article
- Sustained delivery of triamcinolone acetonide from a thermosensitive microemulsion gel system for the treatment of sensorineural hearing loss.Drug delivery · 2023Article
- PEDOT:PSS-coated platinum electrodes for neural stimulation.APL bioengineering · 2023Article
- Computational Modeling of Diffusion-Based Delamination for Active Implantable Medical Devices.Bioengineering (Basel, Switzerland) · 2023Article
- Article
- Cochlear implants: Causes, effects and mitigation strategies for the foreign body response and inflammation.Hearing research · 2022Review
- Nanomaterials for Inner Ear Diseases: Challenges, Limitations and Opportunities.Materials (Basel, Switzerland) · 2022Review
- Numerical Evaluation on Residual Thermal Stress-Induced Delamination at PDMS-Metal Interface of Neural Prostheses.Micromachines · 2021Article
- Biocompatibility of Platinum Nanoparticles in BrainFrontiers in neuroscience · 2021Article
- Gels, jets, mosquitoes, and magnets: a review of implantation strategies for soft neural probes.Journal of neural engineering · 2020Review
- Electrochemistry of Graphene Nanoplatelets Printed Electrodes for Cortical Direct Current Stimulation.Frontiers in neuroscience · 2020Article
- Low-Temperature Atomic Layer Deposited Oxide on Titanium Nitride Electrodes Enables Culture and Physiological Recording of Electrogenic Cells.Frontiers in neuroscience · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Despite the technological progress made with cochlear implants (CI), impedances and their diagnosis remain a focus of interest. Increases in impedance have been related to technical defects of the electrode as well as inflammatory and/or fibrosis along the electrode. Recent studies have demonstrated highly increased impedances as the result of corroded platinum (Pt) electrode contacts. This in vitro study examined the effects of Pt ions and compounds generated by corrosion of the electrode contacts of a human CI on cell metabolism. Since traces of solid Pt in surrounding cochlear tissues have been reported, the impact of commercially available Pt nanoparticles (Pt-NP, size 3 nm) on the cell culture model was also determined. For this purpose, the electrode contacts were electrically stimulated in a 0.5% aqueous NaCl solution for four weeks and the mass fraction of the platinum dissolute (Pt-Diss) was determined by mass spectrometry (ICP-MS). Metabolic activity of the murine fibroblasts (NIH 3T3) and the human neuroblastoma (SH-SY5Y) cells was determined using the WST-1 assay following exposure to Pt-Diss and Pt-NP. It was found that 5-50 μg/ml of the Pt-NP did not affect the viability of both cell types. In contrast, 100 μg/ml of the nanoparticles caused significant loss in metabolic activity. Furthermore, transmission electron microscopy (TEM) revealed mitochondrial swelling in both cell types indicating cytotoxicity. Additionally, TEM demonstrated internalized Pt-NP in NIH 3T3 cells in a concentration dependent manner, whereas endocytosis in SH-SY5Y cells was virtually absent. In comparison with the Pt-NP, the corrosion products (Pt-Diss) with concentrations between 1.64 μg/ml and 8.2 μg/ml induced cell death in both cell lines in a concentration dependent manner. TEM imaging revealed both mitochondrial disintegration and swelling of the endoplasmic reticulum, suggesting that Pt ions trigger cytotoxicity in both NIH 3T3 and SH-SY5Y cell lines by interacting with the respiratory chain.