Evidence map›Paper›PMID 29763442›Full record

ArticlePloS one2018

Platinum corrosion products from electrode contacts of human cochlear implants induce cell death in cell culture models.

Kirsten Wissel, Gudrun Brandes, Nils Pütz, Gian Luigi Angrisani, Jan Thieleke, Thomas Lenarz, Martin Durisin

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 1 synthesis or guideline pooled it, 50 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. In vivo microelectrode arrays for neuroscience.Nature reviews. Methods primers · 2025
    Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Kirsten WisselDepartment of Otorhinolaryngology, Hannover Medical School, Hannover, Germany.ORCID 0000-0001-5535-8833
Gudrun BrandesInstitute of Neuroanatomy and Cell Biology, Center of Anatomy and Cell Biology, Hannover Medical School, Hannover, Germany.
Nils PützDepartment of Otorhinolaryngology, Hannover Medical School, Hannover, Germany.
Gian Luigi AngrisaniInstitute of Materials Science, Leibniz University Hannover, Garbsen, Germany.
Jan ThielekeInstitute of Inorganic Chemistry, Leibniz University Hannover, Hannover, Germany.
Thomas LenarzDepartment of Otorhinolaryngology, Hannover Medical School, Hannover, Germany.
Martin DurisinDepartment of Otorhinolaryngology, Hannover Medical School, Hannover, Germany.
Medizinische Hochschule Hannover · DELeibniz University Hannover · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Despite the technological progress made with cochlear implants (CI), impedances and their diagnosis remain a focus of interest. Increases in impedance have been related to technical defects of the electrode as well as inflammatory and/or fibrosis along the electrode. Recent studies have demonstrated highly increased impedances as the result of corroded platinum (Pt) electrode contacts. This in vitro study examined the effects of Pt ions and compounds generated by corrosion of the electrode contacts of a human CI on cell metabolism. Since traces of solid Pt in surrounding cochlear tissues have been reported, the impact of commercially available Pt nanoparticles (Pt-NP, size 3 nm) on the cell culture model was also determined. For this purpose, the electrode contacts were electrically stimulated in a 0.5% aqueous NaCl solution for four weeks and the mass fraction of the platinum dissolute (Pt-Diss) was determined by mass spectrometry (ICP-MS). Metabolic activity of the murine fibroblasts (NIH 3T3) and the human neuroblastoma (SH-SY5Y) cells was determined using the WST-1 assay following exposure to Pt-Diss and Pt-NP. It was found that 5-50 μg/ml of the Pt-NP did not affect the viability of both cell types. In contrast, 100 μg/ml of the nanoparticles caused significant loss in metabolic activity. Furthermore, transmission electron microscopy (TEM) revealed mitochondrial swelling in both cell types indicating cytotoxicity. Additionally, TEM demonstrated internalized Pt-NP in NIH 3T3 cells in a concentration dependent manner, whereas endocytosis in SH-SY5Y cells was virtually absent. In comparison with the Pt-NP, the corrosion products (Pt-Diss) with concentrations between 1.64 μg/ml and 8.2 μg/ml induced cell death in both cell lines in a concentration dependent manner. TEM imaging revealed both mitochondrial disintegration and swelling of the endoplasmic reticulum, suggesting that Pt ions trigger cytotoxicity in both NIH 3T3 and SH-SY5Y cell lines by interacting with the respiratory chain.

Indexed as

AnimalsCell Culture TechniquesCell DeathCell Line, TumorCell SurvivalCochlear ImplantationCochlear ImplantsCorrosionElectrodesEndocytosisEndoplasmic ReticulumHumansMetal NanoparticlesMiceMitochondriaNIH 3T3 CellsPlatinum

Identifiers

PMID29763442
PMCPMC5953457
OpenAlexW2804012949

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.