ArticleThe British journal of radiology2018
Evaluating the effect of increased pitch, iterative reconstruction and dual source CT on dose reduction and image quality.
Article in The British journal of radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- A method for distance accuracy evaluation on the reformatted oblique plane of CT images.Physical and engineering sciences in medicine · 2026Article
- Quantitative Assessment of the Effects of Scatter Radiation on Image Quality During Extremity Radiography at a Leading Tertiary Hospital in Ghana: An Experimental Pilot Study.Health science reports · 2026Article
- Advancements in radiation dose reduction for pediatric CT head Imaging: A scoping review of emerging Technologies, Protocols, and optimization strategies.Technical innovations & patient support in radiation oncology · 2026Review
- Effects of trauma mattress on dose and image quality of paediatric whole-body computed tomography examinations.BMC medical imaging · 2025Article
- Development of optimised protocols for paediatric whole-body computed tomography examinations: a figure-of-merit approach.BMC medical imaging · 2025Article
- Influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting detector CT.Scientific reports · 2024Article
- Multi-slice computed tomographic analysis and identification of remarkable anatomical types of segmental bronchi in bilateral inferior lobes: based on extensive data.Quantitative imaging in medicine and surgery · 2023Article
- Identification of anatomical types of segmental bronchi in right middle lobe using multi-slice CT.Surgical and radiologic anatomy : SRA · 2023Article
- Radiation dose and image quality of high-pitch emergency abdominal CT in obese patients using third-generation dual-source CT (DSCT).Scientific reports · 2019Article
- Management of incidental pulmonary nodule in CT: a survey by the Italian College of Chest Radiology.La Radiologia medica · 2019Article
- Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study.Journal of medical signals and sensorsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo compare radiation dose and image quality of thoracoabdominal scans obtained with a high-pitch protocol (pitch 3.2) and iterative reconstruction (Sinogram Affirmed Iterative Reconstruction) in comparison to standard pitch reconstructed with filtered back projection (FBP) using dual source CT.
methods114 CT scans (Somatom Definition Flash, Siemens Healthineers, Erlangen, Germany), 39 thoracic scans, 54 thoracoabdominal scans and 21 abdominal scans were performed. Analysis of three protocols was undertaken; pitch of 1 reconstructed with FBP, pitch of 3.2 reconstructed with SAFIRE, pitch of 3.2 with stellar detectors reconstructed with SAFIRE. Objective and subjective image analysis were performed. Dose differences of the protocols used were compared.
resultsDose was reduced when comparing scans with a pitch of 1 reconstructed with FBP to high-pitch scans with a pitch of 3.2 reconstructed with SAFIRE with a reduction of volume CT dose index of 75% for thoracic scans, 64% for thoracoabdominal scans and 67% for abdominal scans. There was a further reduction after the implementation of stellar detectors reflected in a reduction of 36% of the dose-length product for thoracic scans. This was not at the detriment of image quality, contrast-to-noise ratio, signal-to-noise ratio and the qualitative image analysis revealed a superior image quality in the high-pitch protocols.
conclusionThe combination of a high pitch protocol with iterative reconstruction allows significant dose reduction in routine chest and abdominal scans whilst maintaining or improving diagnostic image quality, with a further reduction in thoracic scans with stellar detectors. Advances in knowledge: High pitch imaging with iterative reconstruction is a tool that can be used to reduce dose without sacrificing image quality.