Evidence map›Paper›PMID 29761001›Full record

ArticleBiomedical optics express2018

Multiscale nonlinear microscopy and widefield white light imaging enables rapid histological imaging of surgical specimen margins.

Michael G Giacomelli, Tadayuki Yoshitake, Lucas C Cahill, Hilde Vardeh, Liza M Quintana, Beverly E Faulkner-Jones, Jeff Brooker, James L Connolly, James G Fujimoto

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
5.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Rapid examination of lung tissues by nonlinear microscopy.American journal of clinical pathology · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Harnessing non-destructive 3D pathology.Nature biomedical engineering · 2021
    Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Michael G GiacomelliMassachusetts Institute of Technology, Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, 32 Vassar Street, Cambridge, MA 02139,USA.
Tadayuki YoshitakeMassachusetts Institute of Technology, Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, 32 Vassar Street, Cambridge, MA 02139,USA.
Lucas C CahillMassachusetts Institute of Technology, Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, 32 Vassar Street, Cambridge, MA 02139,USA.
Hilde VardehHarvard Medical School, Department of Pathology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215, USA.
Liza M QuintanaHarvard Medical School, Department of Pathology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215, USA.
Beverly E Faulkner-JonesHarvard Medical School, Department of Pathology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215, USA.
Jeff BrookerThorlabs Advanced Imaging Group, 108 Powers Court, Sterling, VA 20166, USA.
James L ConnollyHarvard Medical School, Department of Pathology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215, USA.
James G FujimotoMassachusetts Institute of Technology, Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, 32 Vassar Street, Cambridge, MA 02139,USA.
Beth Israel Deaconess Medical Center · USMassachusetts Institute of Technology · USThorlabs (Germany) · DE

Funding

OPTICAL BIOPSY USING OPTICAL COHERENCE TOMOGRAPHYR01CA075289 · NCI · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI FUJIMOTO, JAMES G, MASHIMO, HIROSHI · 1997 to 2018
$4.8M
Intraoperative real time breast cancer margin assessment with nonlinear microscopR01CA178636 · NCI · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI CONNOLLY, JAMES, FUJIMOTO, JAMES G · 2013 to 2018
$1.7M
Two-Photon Fluorescence Lifetime Microscopy for Breast and Thyroid Cancer MarginF32CA183400 · NCI · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI GIACOMELLI, MICHAEL GENE · 2014 to 2016
$164k
NCI NIH HHS F32 CA183400NCI NIH HHS R01 CA178636
6 · The paper itself

Abstract

The ability to histologically assess surgical specimens in real-time is a long-standing challenge in cancer surgery, including applications such as breast conserving therapy (BCT). Up to 40% of women treated with BCT for breast cancer require a repeat surgery due to postoperative histological findings of close or positive surgical margins using conventional formalin fixed paraffin embedded histology. Imaging technologies such as nonlinear microscopy (NLM), combined with exogenous fluorophores can rapidly provide virtual H&E imaging of surgical specimens without requiring microtome sectioning, facilitating intraoperative assessment of margin status. However, the large volume of typical surgical excisions combined with the need for rapid assessment, make comprehensive cellular resolution margin assessment during surgery challenging. To address this limitation, we developed a multiscale, real-time microscope with variable magnification NLM and real-time, co-registered position display using a widefield white light imaging system. Margin assessment can be performed rapidly under operator guidance to image specific regions of interest located using widefield imaging. Using simulated surgical margins dissected from human breast excisions, we demonstrate that multi-centimeter margins can be comprehensively imaged at cellular resolution, enabling intraoperative margin assessment. These methods are consistent with pathology assessment performed using frozen section analysis (FSA), however NLM enables faster and more comprehensive assessment of surgical specimens because imaging can be performed without freezing and cryo-sectioning. Therefore, NLM methods have the potential to be applied to a wide range of intra-operative applications.

Indexed as

(170.2520) Fluorescence microscopy(170.4580) Optical diagnostics for medicine(170.4730) Optical pathology(180.4315) Nonlinear microscopy

Identifiers

PMID29761001
PMCPMC5946802
OpenAlexW2801745885

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.