Effects of an intra-ventricular assist device on the stroke volume of failing ventricle: Analysis of a mock circulatory system.

Shidong Zhu, Lin Luo, Bibo Yang, Kai Ni, Qian Zhou, Xinghui Li, Xiaohao Wang

Open access · bronzeAbstract read
In one paragraph

Article in Technology and health care : official journal of the European Society for Engineering and Medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. [Application of hemodynamic optimization in the design of artificial heart].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Shidong ZhuDivision of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China.
Lin LuoDivision of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China.
Bibo YangCardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China.
Kai NiDivision of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China.
Qian ZhouDivision of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China.
Xinghui LiDivision of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China.
Xiaohao WangDivision of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China.
University Town of Shenzhen · CNCapital Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA novel intra-ventricular assist device (iVAD) was established as a new pulsatile assist device to address various disadvantages, such as bulky configuration and reduced arterial pulsatility, observed in conventional ventricular assist devices.

objectiveAnalyzed the native left ventricular stroke volume (SV) after iVAD support in vitro.

methodsThe SV of iVAD was examined in a home-designed mock circulatory system (MCS) at different heart rates and drive pressures and the SV of a failure ventricle was examined with iVAD at 75, 90, 120 bpm and 120-180 mmHg drive pressure after iVAD support. Data pertaining to native left ventricular SV before and after iVAD support were compared.

resultsThe native ventricular SV was improved by iVAD when its drive pressure (DP) was slightly greater than that of the mock system. Conversely, the native ventricular SV was decreased when DP was much greater than that (150 mmHg) of MCS. A high DP had a significant effect on SV.

conclusionsThe proposed device improved the dysfunctional native left ventricular SV when DP of iVAD was slightly greater than that of MCS. However, iVAD reduced the SV when the drive pressure was greater than that of MCS.

Indexed as

Heart-Assist DevicesModels, CardiovascularEquipment DesignHeart FailureHeart VentriclesHumansPulsatile FlowStroke VolumeLeft ventricular assist devicemock circulatory systempulsatile pumpstroke volume

Identifiers

PMID29758970
PMCPMC6004985
OpenAlexW2802872630

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.