ArticlePloS one2018
A surgical simulator for peeling the inner limiting membrane during wet conditions.
Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A systematic review of simulation-based training tools for technical and non-technical skills in ophthalmology.Eye (London, England) · 2020Pooled it
- Advancements in robotic surgery for vitreoretinal diseases: current trends and the future.Japanese journal of ophthalmology · 2025Review
- Evaluation of (Shared) Autonomy in Robot-Assisted Vitreoretinal Surgery Using a Surgical Model.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025Article
- A custom-made vitreoretinal surgical simulator using a silicone mold.BMC ophthalmology · 2023Article
- Bionic eye system mimicking microfluidic structure and intraocular pressure for glaucoma surgery training.PloS one · 2022Article
- A force measurement platform for a vitreoretinal surgical simulator using an artificial eye module integrated with a quartz crystal resonator.Microsystems & nanoengineering · 2022Article
- The Surgeon's Role in Inducing and Controlling Motion Errors During Intraocular Membrane Peeling ProceduresTurkish journal of ophthalmology · 2021Article
- Development of a Spherical Model with a 3D Microchannel: An Application to Glaucoma Surgery.Micromachines · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The present study was performed to establish a novel ocular surgery simulator for training in peeling of the inner limited membrane (ILM). This simulator included a next-generation artificial ILM with mechanical properties similar to the natural ILM that could be peeled underwater in the same manner as in actual surgery. An artificial eye consisting of a fundus and eyeball parts was fabricated. The artificial eye was installed in the eye surgery simulator. The fundus part was mounted in the eyeball, which consisted of an artificial sclera, retina, and ILM. To measure the thickness of the fabricated ILM on the artificial retina, we calculated the distance of the step height as the thickness of the artificial ILM. Two experienced ophthalmologists then assessed the fabricated ILM by sensory evaluation. The minimum thickness of the artificial ILM was 1.9 ± 0.3 μm (n = 3). We were able to perform the peeling task with the ILM in water. Based on the sensory evaluation, an ILM with a minimum thickness and 1000 degrees of polymerization was suitable for training. We installed the eye model on an ocular surgery simulator, which allowed for the performance of a sequence of operations similar to ILM peeling. In conclusion, we developed a novel ocular surgery simulator for ILM peeling. The artificial ILM was peeled underwater in the same manner as in an actual operation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.