Evidence map›Paper›PMID 29747465›Full record

ArticleBioengineering (Basel, Switzerland)2018

Guiding Device for the Patellar Cut in Total Knee Arthroplasty: Design and Validation.

Erica L Rex, Cinzia Gaudelli, Emmanuel M Illical, John Person, Karen C T Arlt, Barry Wylant, Carolyn Anglin

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Erica L RexBiomedical Engineering and McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB T2N 1N4, Canada. rexe4@hotmail.com.
Cinzia GaudelliSection of Orthopaedic Surgery, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 1N4, Canada. cinzia.gaudelli@gmail.com.
Emmanuel M IllicalDepartment of Orthopaedic Surgery, SUNY Downstate Medical Center, Brooklyn, NY 11203, USA. eillical@gmail.com.
John PersonBox 13 Engineering, Calgary, AB T3L 2P5, Canada. john@box13eng.com.
Karen C T ArltBiomedical Engineering and McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB T2N 1N4, Canada. karen.ct.arlt@gmail.com.
Barry WylantQ Industrial Design Corporation, Calgary, AB T2T 0E7, Canada. bwylant@ucalgary.ca.ORCID 0000-0003-1701-0187
Carolyn AnglinBiomedical Engineering and McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB T2N 1N4, Canada. carolyn.anglin@gmail.com.ORCID 0000-0003-3483-8066
University of Calgary · CASUNY Downstate Health Sciences University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An incorrect cut of the patella (kneecap) during total knee arthroplasty, affects the thickness in different quadrants of the patella, leading to pain and poor function. Because of the disadvantages of existing devices, many surgeons choose to perform the cut freehand. Given this mistrust of existing devices, a quick, but accurate, method is needed that guides the cut, without constraining the surgeon. A novel device is described that allows the surgeon to mark a line at the desired cutting plane parallel to the front (anterior) surface using a cautery tool, remove the device, and then align the saw guide, reamer, or freehand saw with the marked line to cut the patella. The device was tested on 36 artificial patellae, custom-molded from two shapes considered easier and harder to resect accurately, and eight paired cadaveric specimens, each in comparison to the conventional saw guide technique. The mediolateral angle, superoinferior angle, difference from intended thickness, and time were comparable or better for the new device. Addressing the remaining outliers should be possible through additional design changes. Use of this guidance device has the potential to improve patellar resection accuracy, as well as provide training to residents and a double-check and feedback tool for expert surgeons.

Indexed as

devicepatellaresectiontotal knee arthroplastyvalidation

Identifiers

PMID29747465
PMCPMC6027333
OpenAlexW2800918199

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.