Evidence map›Paper›PMID 29744245›Full record

ArticleTurkish journal of anaesthesiology and reanimation2018

Reliability of Passive Leg Raising, Stroke Volume Variation and Pulse Pressure Variation to Predict Fluid Responsiveness During Weaning From Mechanical Ventilation After Cardiac Surgery: A Prospective, Observational Study.

Christoph Karl Hofer, Martin Geisen, Sonja Hartnack, Omer Dzemali, Michael Thomas Ganter, Andreas Zollinger

Open access · diamondAbstract read
In one paragraph

Article in Turkish journal of anaesthesiology and reanimation, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Observational
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Christoph Karl HoferInstitute of Anaesthesiology and Intensive Care Medicine, Triemli Hospital Zurich, Switzerland.ORCID 0000-0003-1871-0521
Martin GeisenInstitute of Anaesthesiology and Intensive Care Medicine, Triemli Hospital Zurich, Switzerland.ORCID 0000-0001-9912-6073
Sonja HartnackSection of Epidemiology, Vetsuisse Faculty, University of Zurich, Switzerland.ORCID 0000-0002-5757-5708
Omer DzemaliDivision of Cardiac Surgery, Triemli City Hospital Zurich, Switzerland.ORCID 0000-0001-7910-5152
Michael Thomas GanterInstitute of Anaesthesiology, Kantonsspital Winterthur, Switzerland.ORCID 0000-0003-1234-1833
Andreas ZollingerInstitute of Anaesthesiology and Intensive Care Medicine, Triemli Hospital Zurich, Switzerland.ORCID 0000-0002-8482-5645
CARE USA · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveDuring assisted ventilation and spontaneous breathing, functional haemodynamic parameters, including stroke volume variation (SVV) and pulse pressure variation (PPV), are of limited value to predict fluid responsiveness, and the passive leg raising (PLR) manoeuvre has been advocated as a surrogate method. We aimed to study the predictive value of SVV, PPV and PLR for fluid responsiveness during weaning from mechanical ventilation after cardiac surgery.

methodsHaemodynamic variables and fluid responsiveness were assessed in 34 patients. Upon arrival at the intensive care unit, measurements were performed during continuous mandatory ventilation (CMV) and spontaneous breathing with pressure support (PSV) and after extubation (SPONT). The prediction of a positive fluid responsiveness (defined as stroke volume increase >15% after fluid administration) was tested by calculating the specific receiver operating characteristic (ROC) curves.

resultsA significant increase in stroke volumes was observed during CMV, PSV and SPONT after fluid administration. There were 19 fluid responders (55.9%) during CMV, with 22 (64.7%) and 13 (40.6%) during PSV and SPONT, respectively. The predictive value for a positive fluid responsiveness (area under the ROC curve) for SVV was 0.88, 0.70 and 0.56; was 0.83, 0.69 and 0.48 for PPV; was 0.72, 0.74 and 0.70 for PLR during CMV, PSV and SPONT, respectively.

conclusionDuring mechanical ventilation, adequate prediction of fluid responsiveness using SVV and PPV was observed. However, during spontaneous breathing, the reliability of SVV and PPV was poor. In this period, PLR as a surrogate was able to predict fluid responsiveness better than SVV or PPV but was less reliable than previously reported.

Indexed as

functional haemodynamic parameterpassive leg raisingpulse contour analysispulse pressure variationStroke volume variation

Identifiers

PMID29744245
PMCPMC5937456
OpenAlexW2806136469

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.