Preoperative evaluation of bone quality for dental implantation using an ultrasound axial transmission device in an ex vivo model.

Shinsuke Okada, Akira Kawano, Hiroshi Oue, Yosuke Takeda, Miyuki Yokoi, Katsunori Koretake, Kazuhiro Tsuga

Abstract read
In one paragraph

Article in Clinical and experimental dental research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shinsuke OkadaDepartment of Advanced Prosthodontics, Graduate School of Biomedical & Health Sciences Hiroshima University Hiroshima Japan.
Akira KawanoDepartment of Advanced Prosthodontics, Graduate School of Biomedical & Health Sciences Hiroshima University Hiroshima Japan.
Hiroshi OueDepartment of Advanced Prosthodontics, Graduate School of Biomedical & Health Sciences Hiroshima University Hiroshima Japan.
Yosuke TakedaDepartment of Advanced Prosthodontics, Graduate School of Biomedical & Health Sciences Hiroshima University Hiroshima Japan.
Miyuki YokoiDepartment of Advanced Prosthodontics, Graduate School of Biomedical & Health Sciences Hiroshima University Hiroshima Japan.
Katsunori KoretakeDepartment of Advanced Prosthodontics, Graduate School of Biomedical & Health Sciences Hiroshima University Hiroshima Japan.
Kazuhiro TsugaDepartment of Advanced Prosthodontics, Graduate School of Biomedical & Health Sciences Hiroshima University Hiroshima Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigated the clinical utility of an ultrasound axial transmission device in preoperative evaluation of bone quality for dental implantation, by clarifying the relationship between cortical bone speed of sound (cSOS), insertion torque values (ITV), and implant stability quotient (ISQ) in porcine femur bone. Eleven fresh porcine femurs, without soft tissue, were prepared. The cSOS of these bones were measured using the axial transmission device. Bone mineral density (BMD) and porosity (Po) were measured in cortical bone samples obtained from the region of ultrasound measurements by X-ray microcomputed tomography. Thirty-three implants were inserted into these samples (three implants per bone sample), and ITV and ISQ were measured for all implants. Then, cortical bone thickness (CbTh) of the area for implantation was measured for all implants using a micrometer. The mean cSOS was 3962 m/s; mean BMD and Po were 0.822 g/cm2 and 0.185%, respectively. cSOS and BMD values were positively correlated, and cSOS values and Po values were negatively correlated. Mean ITV, ISQ, and CbTh were 37.95 Ncm, 71.172, and 2.869 mm, respectively. There was a positive correlation between cSOS values and ISQ values. The cSOS of each bone did not correlate with ITV for all of the bone samples. However, when the CbTh ranges from 3.0 to 3.5 mm, ITV are correlated with cSOS. These findings suggest that cSOS, which reflects the cortical bone quality, may be clinical utility as a preoperative diagnosis of the implant.