ArticleScientific reports2018
Setup errors and effectiveness of Optical Laser 3D Surface imaging system (Sentinel) in postoperative radiotherapy of breast cancer.
Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 20 citations in OpenAlex.
- The impact of orthogonal image-guided frequency on positioning error correction and dose in postoperative radiotherapy for breast cancer.BMC cancer · 2026Article
- Evaluation of the accuracy of a surface-guided radiotherapy system for patient positioning in radiotherapy of breast cancer.Physics and imaging in radiation oncology · 2026Article
- Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup.Radiation oncology (London, England) · 2024Article
- Surface-guided radiotherapy systems in locoregional deep inspiration breath hold radiotherapy for breast cancer - a multicenter study on the setup accuracy.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2024Article
- ESTRO-ACROP guideline for positioning, immobilisation and setup verification for local and loco-regional photon breast cancer irradiation.Technical innovations & patient support in radiation oncology · 2023Article
- The factors of fiducial marker motions and individual margin assessment in postoperative breast cancer radiotherapy.Annals of translational medicine · 2022Article
- Feasibility of surface guided radiotherapy for patient positioning in breast radiotherapy versus conventional tattoo-based setups- a systematic review.Technical innovations & patient support in radiation oncology · 2022Article
- Detection of setup errors with a body-surface laser-scanning system for whole-breast irradiation after breast-conserving surgery.Journal of applied clinical medical physics · 2022Article
- AlignRTReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2022Article
- Application of Optical Laser 3D Surface imaging system (Sentinel) in breast cancer radiotherapy.Scientific reports · 2020Article
- Development of twist-correction system for radiotherapy of head and neck cancer patients.Journal of applied clinical medical physics · 2019Article
- AlignRTJournal of applied clinical medical physics · 2019Article
- Overexpression of retinoblastoma‑binding protein 4 contributes to the radiosensitivity of AGS gastric cancer cells via phosphoinositide3‑kinase/protein kinase B pathway suppression.Molecular medicine reports · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Breast-conserving surgery (BCS) plus postoperative radiotherapy has become the standard treatment for early-stage breast cancer. The aim of this study was to compare the setup accuracy of optical surface imaging by the Sentinel system with cone-beam computerized tomography (CBCT) imaging currently used in our clinic for patients received BCS. Two optical surface scans were acquired before and immediately after couch movement correction. The correlation between the setup errors as determined by the initial optical surface scan and CBCT was analyzed. The deviation of the second optical surface scan from the reference planning CT was considered an estimate for the residual errors for the new method for patient setup correction. The consequences in terms for necessary planning target volume (PTV) margins for treatment sessions without setup correction applied. We analyzed 145 scans in 27 patients treated for early stage breast cancer. The setup errors of skin marker based patient alignment by optical surface scan and CBCT were correlated, and the residual setup errors as determined by the optical surface scan after couch movement correction were reduced. Optical surface imaging provides a convenient method for improving the setup accuracy for breast cancer patient without unnecessary imaging dose.
Indexed as
Identifiers