ArticleEuropean radiology2018
Is MRI equivalent to CT in the guidance of TAVR? A pilot study.
Article in European radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 35 citations in OpenAlex.
- Feasibility Study for Dual Phase Free Breathing 3D bSSFP MRA With Preserved Eddy-Current Tolerance With Adaptive k-Space Lengths (PETAL) Acquisition.Magnetic resonance in medicine · 2026Article
- Uncertainty-Guided Active Learning for Access Route Segmentation and Planning in Transcatheter Aortic Valve Implantation.Journal of imaging · 2025Article
- Cardiac Magnetic Resonance for Structural Aortic Valve Stenosis Procedures.Journal of clinical medicine · 2024Review
- A Novel Protocol for Contrast-Free Transcatheter Aortic Valve Replacement Evaluation and Implantation.Journal of the Society for Cardiovascular Angiography & Interventions · 2024Article
- Zero-contrast imaging for the assessment of transcatheter aortic valve implantation in candidates with renal dysfunction.Renal failure · 2023Article
- The feasibility of relaxation-enhanced angiography without contrast and triggering for preprocedural planning of transcatheter aortic valve implantation.Frontiers in cardiovascular medicine · 2023Article
- Article
- Preoperative TAVR Planning: How to Do It.Journal of clinical medicine · 2022Review
- Multi-parametric approach to predict prosthetic valve size using CMR and clinical data: insights from SAVR.The international journal of cardiovascular imaging · 2021Article
- Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.Frontiers in cardiovascular medicine · 2021Review
- TAVI imaging: over the echocardiography.La Radiologia medica · 2020Review
- Non-contrast MRI protocol for TAVI guidance: quiescent-interval single-shot angiography in comparison with contrast-enhanced CT.European radiology · 2020Article
- CT and MR imaging prior to transcatheter aortic valve implantation: standardisation of scanning protocols, measurements and reporting-a consensus document by the European Society of Cardiovascular Radiology (ESCR).European radiology · 2020Article
- Aortic roots assessment by an automated three-dimensional transesophageal echocardiography: an intra-individual comparison.The international journal of cardiovascular imaging · 2019Article
- Transcatheter aortic valve replacement with a focus on transcarotid: a review of the current literature.Annals of translational medicine · 2019Review
- White paper on mitigating risk factors for acute kidney injury in TAVR: A protocol to decrease TAVR-associated AKI.Indian heart journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo compare a comprehensive cardiovascular magnetic resonance imaging (MRI) protocol with contrast-enhanced computed tomography angiography (CTA) for guidance in transcatheter aortic valve replacement (TAVR) evaluation. METHODS AND
resultsNon-contrast three-dimensional (3D) 'whole heart' MRI imaging for aortic annulus sizing and measurements of coronary ostia heights, contrast-enhanced MRI angiography (MRA) for evaluation of transfemoral routes as well as aortoiliofemoral-CTA were performed in 16 patients referred for evaluation of TAVR. Aortic annulus measurements by MRI and CTA showed a very strong correlation (r=0.956, p<0.0001; effective annulus area for MRI 430±74 vs. 428±78 mm
conclusionsIn patients referred for TAVR, MRI measurements of aortic annulus and minimal aortoiliofemoral diameters showed good to excellent agreement. Decisions based on MRI measurements regrading prosthesis sizing and transfemoral access would not have modified TAVR-strategy as compared to a CTA-based choice. KEY POINTS: • 'Whole heart' MRI and CTA measurements of aortic annulus correlate very strongly. • MRI- and CTA-based prostheses sizing are in excellent agreement. • MRA and CTA equally guide TAVR access strategy.
Indexed as
Identifiers
What OpenQuestion holds