Evidence map›Paper›PMID 29732735›Full record

ReviewAdvanced healthcare materials2018

Tissue Engineering at the Blood-Contacting Surface: A Review of Challenges and Strategies in Vascular Graft Development.

Daniel Radke, Wenkai Jia, Dhavan Sharma, Kemin Fena, Guifang Wang, Jeremy Goldman, Feng Zhao

Abstract readReview
In one paragraph

Review in Advanced healthcare materials, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 86 papers.

0numbers the graph read from it
0cells of the map it votes in
86citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

86 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Bioactive materials · 2025
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Biomimetic fabricated tubular graftBioactive materials · 2025
    Article
  16. Expression Analysis ofInternational journal of molecular and cellular medicine · 2025
    Article
  17. Review
  18. Review
  19. Article
  20. Article

26 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Daniel RadkeDepartment of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, 49931, USA.
Wenkai JiaDepartment of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, 49931, USA.
Dhavan SharmaDepartment of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, 49931, USA.
Kemin FenaDepartment of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, 49931, USA.
Guifang WangDepartment of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, 49931, USA.
Jeremy GoldmanDepartment of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, 49931, USA.
Feng ZhaoDepartment of Biomedical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, MI, 49931, USA.ORCID 0000-0003-4138-9027

Funding

Therapeutic Lymphatic Vessel RegenerationR15CA202656 · NCI · MICHIGAN TECHNOLOGICAL UNIVERSITY · PI ZHAO, FENG · 2016 to 2016
$465k
Development of Off-the-shelf Completely Biological Small-Diameter Blood Vessel wiR15HL115521 · NHLBI · MICHIGAN TECHNOLOGICAL UNIVERSITY · PI ZHAO, FENG · 2013 to 2013
$410k
NCI NIH HHS R15 CA202656NHLBI NIH HHS R15 HL115521
6 · The paper itself

Abstract

Tissue engineered vascular grafts (TEVGs) are beginning to achieve clinical success and hold promise as a source of grafting material when donor grafts are unsuitable or unavailable. Significant technological advances have generated small-diameter TEVGs that are mechanically stable and promote functional remodeling by regenerating host cells. However, developing a biocompatible blood-contacting surface remains a major challenge. The TEVG luminal surface must avoid negative inflammatory responses and thrombogenesis immediately upon implantation and promote endothelialization. The surface has therefore become a primary focus for research and development efforts. The current state of TEVGs is herein reviewed with an emphasis on the blood-contacting surface. General vascular physiology and developmental challenges and strategies are briefly described, followed by an overview of the materials currently employed in TEVGs. The use of biodegradable materials and stem cells requires careful control of graft composition, degradation behavior, and cell recruitment ability to ensure that a physiologically relevant vessel structure is ultimately achieved. The establishment of a stable monolayer of endothelial cells and the quiescence of smooth muscle cells are critical to the maintenance of patency. Several strategies to modify blood-contacting surfaces to resist thrombosis and control cellular recruitment are reviewed, including coatings of biomimetic peptides and heparin.

Indexed as

AnimalsBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationCollagenHumansSwineTissue EngineeringTissue ScaffoldsCollagenblood-contacting surfacesendothelializationsurface modificationvascular engineeringvascular grafts

Identifiers

PMID29732735
PMCPMC6105365

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.