Evidence map›Paper›PMID 29732449›Full record

ArticleACS omega2018

Integration of Magnetic Bead-Based Cell Selection into Complex Isolations.

Hannah M Pezzi, David J Niles, Jennifer L Schehr, David J Beebe, Joshua M Lang

Open access · goldAbstract read
In one paragraph

Article in ACS omega, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 29 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Core-Shell Nanoparticles for Pulmonary Drug Delivery.Pharmaceutical nanotechnology · 2025
    Review
  6. Dissection of Gene Expression at the Single-Cell Level: scRNA-seq.Methods in molecular biology (Clifton, N.J.) · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Hannah M PezziDepartment of Biomedical Engineering, Wisconsin Institutes for Medical Research, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705, United States.
David J NilesDepartment of Biomedical Engineering, Wisconsin Institutes for Medical Research, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705, United States.
Jennifer L SchehrDepartment of Medicine and Carbone Cancer Center, University of Wisconsin-Madison, Madison, Wisconsin 53705, United States.
David J BeebeDepartment of Biomedical Engineering, Wisconsin Institutes for Medical Research, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705, United States.
Joshua M LangDepartment of Biomedical Engineering, Wisconsin Institutes for Medical Research, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705, United States.
University of Wisconsin–Madison · US

Funding

UW COMPREHENSIVE CANCER CENTER SUPPORTP30CA014520 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI AMY TRENTHAM-DIETZ · 1985 to 2026
$142.6M
VERSA: An Integrated, Multi-Endpoint Platform for Circulating Tumor Cell AnalysisR01CA181648 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI BERRY, SCOTT M, LANG, JOSHUA MICHAEL · 2014 to 2018
$1.6M
Microchannel cell-based assays to enable cancer researchR33CA137673 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI BEEBE, DAVID J · 2009 to 2011
$1.4M
NCI NIH HHS P30 CA014520NCI NIH HHS R01 CA181648NCI NIH HHS R33 CA137673
6 · The paper itself

Abstract

Magnetic bead-based analyte capture has emerged as a ubiquitous method in cell isolation, enabling the highly specific capture of target populations through simple magnetic manipulation. To date, no "one-size fits all" magnetic bead has been widely adopted leading to an overwhelming number of commercial beads. Ultimately, the ideal bead is one that not only facilitates cell isolation but also proves compatible with the widest range of downstream applications and analytic endpoints. Despite the diverse offering of sizes, coatings, and conjugation chemistries, few studies exist to benchmark the performance characteristics of different commercially available beads; importantly, these bead characteristics ultimately determine the ability of a bead to integrate into the user's assay. In this report, we evaluate bead-based cell isolation considerations, approaches, and results across a subset of commercially available magnetic beads (Dynabeads FlowComps, Dynabeads CELLection, GE Healthcare Sera-Mag SpeedBeads streptavidin-blocked magnetic particles, Dynabeads M-270s, Dynabeads M-280s) to compare and contrast both capture-specific traits (i.e., purity, capture efficacy, and contaminant isolations) and endpoint compatibility (i.e., protein localization, fluorescence imaging, and nucleic acid extraction). We identify specific advantages and contexts of use in which distinct bead products may facilitate experimental goals and integrate into downstream applications.

Identifiers

PMID29732449
PMCPMC5928489
OpenAlexW2796036851

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.