ArticleMagnetic resonance imaging2018

Pancreatic stiffness response to an oral glucose load in obese adults measured by magnetic resonance elastography.

Ruoyun Ji, Jiahui Li, Ziying Yin, Yanqing Liu, Lizhuo Cang, Min Wang, Yu Shi

Abstract read
In one paragraph

Article in Magnetic resonance imaging, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Cross-sectional imaging of the pancreas in diabetes.Abdominal radiology (New York) · 2024
    Review
  3. Review
  4. Article
  5. Review
  6. Quantitative pancreatic MRI: a pathology-based review.The British journal of radiology · 2019
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Ruoyun JiDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang, China.
Jiahui LiDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang, China.
Ziying YinDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Yanqing LiuDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang, China.
Lizhuo CangDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang, China.
Min WangDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang, China.
Yu ShiDepartment of Radiology, Shengjing Hospital of China Medical University, Shenyang, China. Electronic address: 18940259980@163.com.
China Medical University · CNMayo Clinic in Arizona · US

Funding

Magnetic Resonance ElastographyR37EB001981 · NIBIB · MAYO CLINIC ROCHESTER · PI EHMAN, RICHARD L. · 2016 to 2025
$4.0M
Magnetic Resonance ElastographyR01EB001981 · NIBIB · MAYO CLINIC ROCHESTER · PI EHMAN, RICHARD L. · 2003 to 2013
$3.1M
NIBIB NIH HHS R01 EB001981NIBIB NIH HHS R37 EB001981
6 · The paper itself

Abstract

backgroundTo test the feasibility of magnetic resonance elastography (MRE) for assessing changes in pancreatic stiffness of obese adults administered an oral glucose load.

methodsMRE scans were performed on 21 asymptomatic obese volunteers (BMI ≥ 27 kg/m

resultsGood inter-observer agreement was found for image quality at both frequencies (kappa = 0.805 for 40 Hz and 0.762 for 60 Hz). The median overall image quality score was significantly higher in 40 Hz than that of 60 Hz (4 versus 2). At 40 Hz, pancreatic stiffness in response to oral glucose had a decrease of 6.7% (pre vs post: 1.17 ± 0.13 kPa vs 1.08 ± 0.12 kPa; P < 0.001), whereas the change in stiffness was not significant at 60 Hz (pre vs post: 2.01 ± 0.21 kPa vs 2.02 ± 0.24 kPa; P = 0.695). Excellent intersession agreement was found for MRE acquisitions at 40 Hz with an overall intraclass correlation coefficient = 0.947 (95% confidence interval: 0.913-0.967).

conclusionMRE at 40 Hz provides good-quality wave images and high sensitivity to changes in the mechanical properties of pancreatic tissue in obese volunteers after an oral glucose load.

Indexed as

Administration, OralAdultElasticity Imaging TechniquesFeasibility StudiesFemaleGlucoseHumansMaleObesityPancreasProspective StudiesReproducibility of ResultsGlucoseGlucoseMagnetic resonance elastographyObesePancreas

Identifiers

PMID29729951
PMCPMC6183057
OpenAlexW2802609351

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.