4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Cong Zhao, Yuncheng Zhong, Xinhui Duan, You Zhang, Xiaokun Huang, Jing Wang, Mingwu Jin

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Cong ZhaoDepartment of Physics, University of Texas at Arlington, Arlington, TX 76019, United States of America.
Yuncheng ZhongDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.
Xinhui DuanDepartment of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.
You ZhangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.
Xiaokun HuangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.
Jing WangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.
Mingwu JinDepartment of Physics, University of Texas at Arlington, Arlington, TX 76019, United States of America.ORCID 0000-0003-3987-2896
The University of Texas Southwestern Medical Center · USThe University of Texas at Arlington · US

Funding

Next generation 4D-CBCT for lung cancer radiation therapyR01EB020366 · NIBIB · UT SOUTHWESTERN MEDICAL CENTER · PI WANG, JING · 2015 to 2018
$1.4M
Boosting photo-induced cancer therapies through real-time image guidanceR15CA199020 · NCI · UNIVERSITY OF TEXAS ARLINGTON · PI JIN, MINGWU · 2016 to 2016
$415k
Recovery of true scatter in blocked regions for blocker-based scatter correction of CBCTR03EB021600 · NIBIB · UNIVERSITY OF TEXAS ARLINGTON · PI JIN, MINGWU · 2016 to 2017
$154k
NCI NIH HHS R15 CA199020NIBIB NIH HHS R01 EB020366NIBIB NIH HHS R03 EB021600
6 · The paper itself

Abstract

Four-dimensional (4D) x-ray cone-beam computed tomography (CBCT) is important for a precise radiation therapy for lung cancer. Due to the repeated use and 4D acquisition over a course of radiotherapy, the radiation dose becomes a concern. Meanwhile, the scatter contamination in CBCT deteriorates image quality for treatment tasks. In this work, we propose the use of a moving blocker (MB) during the 4D CBCT acquisition ('4D MB') and to combine motion-compensated reconstruction to address these two issues simultaneously. In 4D MB CBCT, the moving blocker reduces the x-ray flux passing through the patient and collects the scatter information in the blocked region at the same time. The scatter signal is estimated from the blocked region for correction. Even though the number of projection views and projection data in each view are not complete for conventional reconstruction, 4D reconstruction with a total-variation (TV) constraint and a motion-compensated temporal constraint can utilize both spatial gradient sparsity and temporal correlations among different phases to overcome the missing data problem. The feasibility simulation studies using the 4D NCAT phantom showed that 4D MB with motion-compensated reconstruction with 1/3 imaging dose reduction could produce satisfactory images and achieve 37% improvement on structural similarity (SSIM) index and 55% improvement on root mean square error (RMSE), compared to 4D reconstruction at the regular imaging dose without scatter correction. For the same 4D MB data, 4D reconstruction outperformed 3D TV reconstruction by 28% on SSIM and 34% on RMSE. A study of synthetic patient data also demonstrated the potential of 4D MB to reduce the radiation dose by 1/3 without compromising the image quality. This work paves the way for more comprehensive studies to investigate the dose reduction limit offered by this novel 4D MB method using physical phantom experiments and real patient data based on clinical relevant metrics.

Indexed as

AlgorithmsPhantoms, ImagingCone-Beam Computed TomographyFour-Dimensional Computed TomographyHumansImage Processing, Computer-AssistedLung NeoplasmsMovementRadiation DosageScattering, Radiation

Identifiers

PMID29722297
PMCPMC5995796
OpenAlexW2802175546

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.