Evidence map›Paper›PMID 29722248›Full record

ArticleThe Korean journal of internal medicine2019

Standardized, musculoskeletal ultrasonographic reference values for healthy Korean adults.

Hyun-Sook Kim, Hae-Rim Kim, Bo Young Kim, Yun Sung Kim, Young Ok Jung, Sung Jae Choi, Hyun-Ok Kim, Jiwon Hwang, Sunggun Lee, Hyoun-Ah Kim and 4 more

Abstract read
In one paragraph

Article in The Korean journal of internal medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Hyun-Sook KimDepartment of Internal Medicine, Soonchunhyang University College of Medicine, Seoul, Korea.
Hae-Rim KimDepartment of Internal Medicine, Konkuk University School of Medicine, Seoul, Korea.
Bo Young KimDepartment of Internal Medicine, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea.
Yun Sung KimDepartment of Internal Medicine, Chosun University College of Medicine, Gwangju, Korea.
Young Ok JungDepartment of Internal Medicine, Jung's Rheumatism Clinic, Seoul, Korea.
Sung Jae ChoiDepartment of Internal Medicine, Korea University College of Medicine, Seoul, Korea.
Hyun-Ok KimDepartment of Internal Medicine, Gyeongsang National University School of Medicine, Jinju, Korea.
Jiwon HwangDepartment of Internal Medicine, National Police Hospital, Seoul, Korea.
Sunggun LeeDepartment of Internal Medicine, Inje University Haeundae Paik Hospital, Busan, Korea.
Hyoun-Ah KimDepartment of Internal Medicine, Ajou University Hospital, Suwon, Korea.
So Young BangDepartment of Internal Medicine, Hanyang University Hospital for Rheumatic Diseases, Seoul, Korea.
Ji-Young ChaiDepartment of Internal Medicine, Bundang Jesaeng Hospital, Seongnam, Korea.
Sung-Hoon ParkDepartment of Internal Medicine, Catholic University of Daegu School of Medicine, Daegu, Korea.
Chong-Hyeon YoonDepartment of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.

Funding

Soonchunhyang University
6 · The paper itself

Abstract

BACKGROUND/

aimsTo define standard reference values for musculoskeletal ultrasonography (MSUS) in Korea.

methodsA total of 251 healthy adults were recruited for this study. Ultrasonography was performed by experienced rheumatologists who had undergone four appropriate training programs in Korea. A General Electric LOGIQ electronic ultrasound device fitted with a 12 MHz linear transducer was employed. Mean values ± standard deviations (SDs) were defined as standard reference values. Intraclass correlation coefficients was employed to evaluate the extent of inter- and intraobserver agreement when MSUS measurements were made.

resultsThe 251 study participants included 122 males. Mean subject age was 28.6 years. The average bone-to-capsule distance of the right-side second and third metacarpophalangeal (MCP) joints were 0.68 and 0.72 mm respectively, and those of the left-side joints 0.62 and 0.68 mm. The cartilage thicknesses of the rightside second and third MCP joints were 0.55 and 0.55 mm, and those of the leftside joints were 0.55 and 0.56 mm, respectively. The bone-to-capsule distances of the right and left wrists were 0.80 and 0.82 mm. In 12.4% of participants (31/251), the erosion score of the humeral head was 1.71. In the right-side knee joint, mean cartilage thicknesses of the medial and lateral condyles were 1.86 and 2.03 mm in longitudinal scans. High overall interobserver agreement was evident after appropriate training that included instruction on standard MSUS methodology.

conclusionWe defined standard reference values for MSUS in healthy Korean adults. The reliabilities of interobserver agreements were high after appropriate training program.

Indexed as

AdultAnatomic LandmarksFemaleHealthy VolunteersHumansMaleMiddle AgedMusculoskeletal SystemObserver VariationPredictive Value of TestsReference ValuesReproducibility of ResultsRepublic of KoreaUltrasonographyYoung AdultEducationMusculoskeletalReference standardsUltrasonography

Identifiers

PMID29722248
PMCPMC6823555

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.