Evidence map›Paper›PMID 29719557›Full record

ArticleInterventional neurology2018

Stent Reconstruction of Carotid Tonsillar Loop Dissection Using Telescoping Peripheral Stents.

Benjamin M Zussman, Bradley A Gross, William J Ares, Cynthia L Kenmuir, Gregory M Weiner, David M Panczykowski, Ashutosh P Jadhav, Tudor G Jovin, Brian T Jankowitz

Open access · bronzeAbstract read
In one paragraph

Article in Interventional neurology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Resolution of complex tandem stroke caused by carotid loop acute dissection using a distal anchorage-stent facilitating technique.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Benjamin M ZussmanNeurosurgery Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Bradley A GrossNeurosurgery Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
William J AresNeurosurgery Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Cynthia L KenmuirNeurology Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Gregory M WeinerNeurosurgery Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
David M PanczykowskiNeurosurgery Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Ashutosh P JadhavNeurology Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Tudor G JovinNeurology Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Brian T JankowitzNeurosurgery Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
University of Pittsburgh Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEndovascular treatment options for internal carotid artery (ICA) dissection with tandem intracranial occlusion are evolving. We report 2 cases of stent reconstruction of carotid loop dissections.

methodsTwo patients with symptomatic ICA dissections of true 360° tonsillar loops and tandem intracranial occlusions were treated with manual aspiration thrombectomy (MAT) and telescoping Zilver self-expanding peripheral stents. Patient demographics, clinical presentations, endovascular techniques, and clinical outcomes were reviewed.

resultsIn both cases, MAT achieved modified Treatment in Cerebral Ischemia scale 2B reperfusion, and complete endovascular reconstruction of the dissected extracranial loop was performed. Both patients had improved pre- to postintervention National Institutes of Health Stroke Scale scores (16 to 0 and 14 to 0), and both had modified Rankin scale scores of 1 at 3-month follow-up.

conclusionsStent reconstruction of complex cerebrovascular anatomy is increasingly feasible with advancements in stent technology and catheter support system design. This technique may be of use to neuroendovascular surgeons who encounter variant ICA anatomy.

Indexed as

Acute strokeArtery dissectionCarotid stentingEndovascular stroke therapy

Identifiers

PMID29719557
PMCPMC5921215
OpenAlexW2790447333

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.