ArticleJournal of radiation research2018
Metal artifact reduction by filter-based dual-energy cone-beam computed tomography on a bench-top micro-CBCT system: concept and demonstration.
Article in Journal of radiation research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 17 citations in OpenAlex.
- A Dual-Energy CBCT With Reduced Scatter and Cone Beam Artifacts Using an X-Ray Source Array and Interlaced Spectral Filters.IEEE transactions on bio-medical engineering · 2026Article
- Refining imaging parameters for dual-energy cone-beam computed tomography in image-guided radiation therapy.Journal of applied clinical medical physics · 2026Article
- Impact of dose allocation between high- and low-kV scans on virtual monoenergetic image quality in developmental dual-energy cone-beam CT for image-guided radiotherapy.Journal of applied clinical medical physics · 2026Article
- Fast, automated optimization of virtual monoenergetic images with the dual-energy image synthesizer for cone-beam CT.Journal of applied clinical medical physics · 2025Article
- Low-cost dual-energy CBCT by spectral filtration of a dual focal spot X-ray source.Scientific reports · 2024Article
- Technical note: TIGRE-DE for the creation of virtual monoenergetic images from dual-energy cone-beam CT.Medical physics · 2024Article
- Dose Reduction and Image Quality Optimization of Pediatric Chest Radiography Using a Tungsten Filter.Bioengineering (Basel, Switzerland) · 2022Article
- Feasibility of dual-energy CBCT by spectral filtration of a dual-focus CNT x-ray source.PloS one · 2022Article
- Challenging Cases of Aortic Prosthesis Dysfunction, the Importance of Multimodality Imaging, a Case Series.Diagnostics (Basel, Switzerland) · 2021Article
- Reducing metal artifacts between implants in cone-beam CT by adjusting angular position of the subject.Oral radiology · 2021Article
- Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study.Dento maxillo facial radiology · 2021Article
- Fast-switching dual energy cone beam computed tomography using the on-board imager of a commercial linear accelerator.Physics in medicine and biology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We evaluated two dual-energy cone-beam computed tomography (DE-CBCT) methodologies for a bench-top micro-CBCT system to reduce metal artifacts on reconstructed images. Two filter-based DE-CBCT methodologies were tested: (i) alternative spectral switching and (ii) simultaneous beam splitting. We employed filters of 0.6-mm-thick tin and 0.1-mm-thick tungsten to generate high- and low-energy spectra from 120 kVp X-rays, respectively. The spectral switching method was imitated by two half scans with different filters (pseudo-switching). Filters were placed and between the X-ray tube and a phantom ('1-u,' '2-u'), a phantom and a flat panel detector ('1-d,' '2-d'), and compared with (iii) two half scans at 80 and 140 kVp [pseudo-(80,140)]. For the splitting method, two half-width filters were aligned along a rotating axis. Projections were separated into halves and merged with corresponding areas of opposed projections after one full rotation. A solid 30-mm-diameter acrylic phantom and an acrylic phantom with four 5-mm-diameter titanium rods were used. DE images were generated by weighted summation of the high- and low-energy images. The blending factor was changed from 0 to +5 in increments of 0.01. Relative errors (REs) of the linear attenuation coefficients of the two phantoms and the contrast-to-noise ratios (CNRs) between the titanium and acrylic regions were compared. All methods showed zero REs except for the method (2-d). CNRs for pseudo-switching with upstream placement were 1.4-fold larger than CNRs for the pseudo-(80,140) method. CNRs for the downstream placements were small. It was concluded that the pseudo-switching method with upstream placement is appropriate for reducing metal artifacts.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.